operation
file: n:\article\cos14310m5-v1_07hpc-en\20130207_cos14310m5-v1.07hpc-en_h-p-cosmos_treadmill_manual.doc
© 2013 h/p/cosmos sports & medical gmbh author: fh [email protected] created 07.02.2013 printed 04.03.2013 page: 30 of 197
5.4
Emergency Stop, stop buttons, stop functions and safety features
In case of emergency, e.g. danger of stumbling and/or falling, etc., grab the front crossbar and/or both side handrails
and jump onto the foot rails (step platforms) with both feet.
The emergency stop button is to be pressed immediately!
h/p/cosmos is in compliance with the norm EN 957-6 and offers more safety features than required, as shown in the
following tables. In all below mentioned cases, all displayed values will be reset to “0”.
N
Use the emergency stop only if in danger.
N
The emergency stop is not to be used as a normal stop key.
Type of Stop
Function
Interface
communication
How to restart
Safety Stop =
Emergency Stop
on UserTerminal
N
palm switch is hit
N
running belt & inclination system stop fast
N
machine is cut off from main power of
drive motor and inclination system
N
display, keyboard and interface inactive
interrupted
during cut-off
from main power
N
wait 1 minute
N
turn palm switch to
the right
N
push “ON” button at
main power switch
N
press START key at
UserTerminal
or new command via
interface
Safety Stop =
Emergency Stop
N
mushroom switch is hit
N
running belt & inclination system stop fast
N
machine is cut off from main power of
drive motor and inclination system
N
display, keyboard and interface inactive
interrupted
during cut-off
from
main power
N
wait 1 minute
N
pull mushroom switch
N
push “ON” button at
main power switch
N
press START key at
UserTerminal
or new command via
interface
Quick Stop
models venus / saturn
Emergency stop
button is connected to
the “quick stop port”
of the UserTerminal
N
mushroom switch is hit
N
running belt & inclination system stop
extremely fast
N
drive motor is used to stop the running belt
very fast
N
machine is
NOT
cut off from main power
of drive motor and inclination system
N
display active, shows “PULL STOP”
N
interface active, but no start, speed or
elevation signal executed
N
keyboard inactive
NOT
interrupted
during
Quick Stop
stage
N
pull mushroom switch
N
„pull-stop“ advice
stays for 10 seconds
N
press START key at
UserTerminal
or new command via
interface