7.4.6
Electrical installation
An overload or voltage drop (even temporary) of more than 20 % of the mains voltage might cause
a malfunction and/or defect and might totally switch off the running machine. In the event of such
high voltage drops or total power failure, the running machine switches off and the running belt
stops. To start again, switch on the running machine at the main ”ON“ switch and press START at
the keyboard.
N
h/p/cosmos running machines are to be installed at a voltage power connection with ground wire (earthing,)
including leakage-current protection switch (interrupter) and according to VDE 0100 or/and the currently valid
regulations and directives. Requirements for special locations, areas and establishments (e.g. medically used
areas) must be strictly adhered to. PE connection (protection-earth contact) is stipulated for all running machines.
The voltage drop between the beginning of the consumer’s installation and the wall socket must not be more than
4 % (DIN VDE 0100-520). It is the consignee’s and user’s personal responsibility to check the correct function of
the mains connection including the outlets. An authorized electrical engineer must check these points for perfect
functioning regularly (1 ... 4 years). Inspections of the electrical installations within the building are not incumbent
on the supplier h/p/cosmos.
N
Read the nameplate of the machine before connecting the machine to the power outlet in order to determine
whether the machine was designed for special voltage supply (e.g. 110 V and 25 A). The standard power supply of
230 V / AC, 50/60 Hz is sufficient for most of the running machines.
N
The bigger running machines (with a size of running surface 190/65 cm models
pulsar 3p and venus / saturn up to 450/300 cm) require a 3 phase AC power supply:
3 x 400 V / 32 A fuse (16 A for models pulsar 3p) and clockwise rotation.
right: CEE power outlet (socket), 5-pin, 16 A
[cos11092]
left: CEE power outlet (socket), 5-pin, 32 A
[cos11090]
Power supply for h/p/cosmos pulsar 3p
400 Volt AC 3~/N/PE f: 50/60 Hz Imax: 16.0 A
3 phase current with clockwise rotation field.
16 A fuse (C characteristic)
Power supply for h/p/cosmos venus and saturn
400 Volt AC 3~/N/PE f: 50/60 Hz Imax: 32.0 A
3 phase current with clockwise rotation field.
32 A fuse (C characteristic)
The mentioned wire colours are applicable for Germany; different colours may be applicable for other countries.
Voltage values for 3-phase voltage power supply:
from L1 to L2: 400 V, from L1 to L3: 400 V, from L2 to L3: 400 V
from L1 to N: 230 V, from L2 to N: 230 V, from L3 to N: 230 V