23
The Oscillator Control Features & Setup Screen
The Features & Setup Screen has the following features:
1
st
Field = The Auto Cycle storage number to be recalled. The number shown in this field will
be the program that will be copied from storage and applied to the running
(operational) mode values when exited from programming mode. The choices are
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, or 10 (surrounded by the auto cycle symbol). When the
value is 0, the existing oscillation values last used will not be over-written. Each
time the Features and Setup screen is opened, the value in this field defaults to 0.
2
nd
Field = Oscillation Rest Location. This setting dictates where the oscillator stops at the
end of an oscillation cycle (and therefore assumed location at the start of an
oscillation cycle). The choices are A, B or C. The factory default setting is B
(center position of oscillation).
1
st
Field
2
nd
Field