37
Carriage Maximum Speed Adjustment:
This sets the maximum speed at which the motor
control will allow (the speed is capped at this set percentage). The variable value range is from
1 to 100 percent of full speed, in increments of 1%. Factory set at 100.
Screen 3:
Wire Feed Over-Current:
This sets the maximum current draw that the
wire feed motor control will allow before activating an error code and
ceasing operation. The variable value range is from 0 to 10 amps in
increments of 1 amp. Factory set at 10 amps.
Wire Feed Maximum Speed:
this variable is used to calibrate the
motor control to suit the wire feed drive motor used. At this writing there
is only one (1) wire feed drive motor available which has a maximum
weld speed of 633 inches per minute [1607 cm/min] and is factory
preset accordingly.
Wire Feed Braking:
This sets the level of wire feed motor braking from instant braking to a
variable degree of pulsed graduated braking. The variable value range is from a reference
value of 1 to 10 in increments of 1. A reference value of 0 provides instant braking whereas a
reference value of 10 provides the slowest, softest pulse braking. Factory set at 1
Wire Feed Response:
This sets the speed correction response (gain) rate. By having the wire
feed motor speed correction rate at a slow response, the motor takes longer to accelerate to
speed and reacts to motor speed variances slower. By having a fast response, the motor will
accelerate to speed quickly, sometimes resulting in over shooting of the preset speed, and
reacting to motor speed variances instantly, sometimes resulting in slight speed oscillation. The
variable value range is from a reference value of 1 to 10 in increments of 1. A reference value
of 1 provides the fastest speed correction rate, whereas a reference value of 10 provides the
slowest, speed correction response rate. Factory set at 1
Wire Feed Maximum Speed Adjustment:
This sets the maximum speed at which the wire
feed motor control will allow (the speed is capped at this set percentage). The variable value
range is from 1 to 100 percent of full speed, in increments of 1%. Factory set at 100.
Screen 4:
Welding Power source Calibration Screen
This screen allows the operator to calibrate the remote welding voltage control and wire feed
speed to match the welding power sources welding voltage output and wire feed speed.
Note:
This screen is only applicable if the welding power source being used can accept
analog control signals (0-10VDC) for remote voltage and remote wire feed speed control.
The operator must first determine the welding voltage output range of the power source used
and also the wire feed speed range of the wire feed that would normally be used with this power
source. This information is normally found in the technical documentation provided with the
welding power source.
633