25
ADVANCED PROGRAMMING MODE
Oscillator Control Motor Setup Screen
The Motor Setup Screen is only available in the Advanced Programming Mode (requiring the
Programming Button to be pressed for more than ten seconds) and has the following features:
1
st
Field = the A and C Orientation. Depending on how the Oscillator Head is mounted
relative to the control, the A & C dwell locations and manual jog (steering) may be
opposite to that expected. This field allows virtual orientation reversal of the
oscillator head. The choices available are either “A B C” or “C B A”. The control
will also reassign limit switch input logic to suit.
2
nd
Field = Centre Position Adjustment (Steering) Increments for Linear Oscillator Heads. The
value in this field sets the incremental distance of the Centre Position Adjustment
(steering). I.e. a large value will result in course steering adjustments, whereas as
a small value will provide finer steering. The value is to be multiplied by 0.01
inches, or 0.01 Cm, depending on the Units of Measure (field 8).
3
rd
Field = Centre Position Adjustment (Steering) Increments for Radial Oscillator Heads. Not
applicable to this model of the PIPE KAT
®
, therefore do not adjust.
4
th
, 5
th
, 6
th
& 7
th
Fields = Units of Travel Per Motor Step. These numeric fields are used to
program how much oscillation travel will be achieved for each step of the oscillator
motor. It is broken into four fields to allow the value to be easily entered. Each
field has a range of 00 to 99. The control will use this total value to determine the
amount of motor motion required to obtain the programmed oscillation. It is
important to know the model of oscillator head being used with the control in order
to calibrate the control to match the oscillator head. The values entered in these
fields must be in units equal to the Units of Measure (field 8).
8
th
Field = Units of Measure. This field determines the units of measure (and increments of
adjustment) for the oscillator width and speeds. The choices available are
“INCHES” or “CM” for the linear heads used on PIPE KAT
®
‘s (the choice of
“DEGREES” is for use with radial oscillator heads only and not applicable for this
model of PIPE KAT
®
). See the “Table of Oscillator Head Values” to find the Units
of Travel per Step for common Gullco Oscillator Heads.
1
st
Field
2
nd
Field
3
rd
Field
4
th
Field
5
th
Field
6
th
Field
7
th
Field
8
th
Field