Low Temperature Sensor Connections - Direct
TX- TX+ GND
E
E
N
N
L
L
N
N
N
L
L
L
24V
DC
N
N
N
L
L
L
N
N
N
L
L
L
E
E
N
N
L
L
E
E
N
N
L
L
TX
-
TX
+
GN
D
†
See
or contact Guidance
Marine if alternative
settings are required.
To Connect a Cable to the RadaScan
Sensor:
1. Unscrew the M4 socket screws around the
inspection hatch and remove the inspection
hatch from the front of the sensor.
2. Remove the screw head from a watertight
cable gland on the inspection hatch.
3. Feed the cable through the screw head and
gland.
4. Connect the cable to the correct socket/
terminal inside the sensor.
5. When all connections have been made,
apply DC4 compound around the seal of
the inspection hatch and replace the hatch.
Tighten all of the cable glands to ensure a
watertight seal.
CAT 5e Cable
RS422 Link
to Vessel’s
DP System
Default IP Addresses:
†
RadaScan Sensor:
192.168.2.231
Subnet Mask:
255.255.255.0
Type 2 Marine Processor (LAN1):
192.168.2.241
Subnet Mask:
255.255.255.0
Mains Power
115VAC 45-65Hz 2.8A
240VAC 45-65Hz 1.2A
Ethernet Link to
RadaScan
Type 2 Marine
Processor
Heater Power
Low Temperature Sensor:
115VAC 45-65Hz 20A
240VAC 45-65Hz 14A
Internal Ethernet Cable
RS422 Link
9600 baud
8 bits
1 stop bit
No parity
Cable
Glands
Radome
Inspection Hatch
20