For Rolls Royce Custom DP format:
DP Feed
Always
Enabled
Allow Refresh
Timer and
Zero Strings
Output when target is visible but not tracked
Null data (gaps in data string)
Available data (actual co-ordinates, status = A)
Zero data (coordinates set to zero, status = V)
Available data (actual co-ordinates, status = A)
For the MT Custom DP format, Available data (actual co-ordinates, status = A) is output when a
target is visible but not tracked. The DP Feed Behaviour options have no effect.
The following behaviour applies when the system is suspended:
For all DP formats except for MT Custom:
DP Feed
Always
Enabled
Allow Refresh
Timer and
Zero Strings
Output when system is suspended
Null data (gaps in data string)
Null data (gaps in data string)
Zero data (coordinates set to zero, status = V
†
)
Zero data (coordinates set to zero, status = V
†
)
DP Message Format and Feed Behaviour (continued)
For the MT Custom DP format, Zero data (coordinates set to zero, status = V) is output when
the system is suspended. The DP Feed Behaviour options have no effect.
†
Denotes that not all of these DP formats include a Status field, but for those that do, it is set
to “V”.
42
Содержание RadaScan View
Страница 69: ......