1 GND
1 RX+
1 RX-
1 TX-
1 TX+
1 GND
1 RX+
1 RX-
1 TX-
1 TX+
l
52
Connect Ethernet Port 0 to the Marine Processor, Serial Port 1 to DP System 1 and Serial Port 0 to DP system 2.
Configure the serial connections as shown below:
1 GND
2 RX+
3 RX-
4 TX-
5 TX+
DP
Feed 1
RS422
Link to DP
System 2
Mains Power
86–264V AC
Serial 1
Ethernet 1
Ethernet 0
Serial 0
Serial 1
Power
Power LED
VFD Screen
Service Connections
RS422 Link
9600 baud
8 bits
1 stop bit
No parity
Ethernet
Link to
Marine
Processor
To Connect Cables to
Power/Serial Plugs:
M
Insert Operation Lever-
tool into slot above
connector-hole in
plug.
R
Whilst holding down
lever, insert cable end
into connector-hole.
C
Release and remove
the lever-tool.
RS422
Link to DP
System 1
1 GND
2 RX+
3 RX-
4 TX-
5 TX+
DP
Feed 2
Serial 0
SceneScan Client and DP Feed Connections
Default Ethernet Settings:
†
IP Address: 192.168.0.86
Subnet Mask:
255.255.255.0
Note: The default IP address
may need to be changed prior
to installation through the
SceneScan Service Interface
software (SSI)
Fuses
†
Contact Guidance
Marine if
alternative settings
are required.
Note: the Ethernet
and the Serial screen
should be connected
at the Sensor only.
Do not terminate at
both ends.
Connect earth cable
to earthing point.
10mm
6.6mm
19.6mm
4.1mm
Note: Either Serial 0 or Serial
1 can be used. The DP feed is
output from both ports.
(Optional)