16
LPA 3000XLS/3200XLS Instruction Manual
Step 3
Insert the stripped power cable wires into the
appropriate terminals on the MASTER OPERATOR
terminal block. The green wire should be inserted
into the GRN terminal, the white wire into WHT, the
blue wire into BLUE, brown wire into BRN, orange
wire into ORG, red wire into RED, and the black wire
into the BLK terminal.
Tighten the set screws against the end of the wires.
Connecting MASTER Operator
Step 4
Insert the stripped wires of the power cable into the
appropriate terminals on the SECOND OPERATOR
terminal block. The green wire should be inserted
into the GRN terminal, the white wire into WHT, the
blue wire into BLUE, brown wire into BRN, orange
wire into ORG, red wire into RED, and the black wire
into the BLK terminal.
Tighten the set screws against the end of the wires.
Connecting SECOND Operator
NEVER SPLICE WIRES
Splicing
permits corrosion and seriously degrades
the wire's ability to carry an adequate
current.
Power Cable from the
Second Operator Arm
WHT
BLU
BRN
ORG
RED
BLK
GRN
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
CYCLE
COM
LOCK
PWR
AU
X
R
LY
C
ONTR
OL OUTPUT
S
MASTER OPER
A
TOR
2ND OPER
A
TOR
C
ONTR
OL INPUT
S
Power Cable from the
Master Operator Arm
RECEIVER
GT
O R
CVR.
WHT
BLU
BRN
ORG
RED
BLK
GRN
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
MASTER OPER
A
TOR
C
ONTR
OL INPUT
S
CLOSE
EDGE
Correct
Wrong
Wrong
Wire
Screwed into
wire insulation
Exposed strands
of wire