background image

  LPA 3000XLS/3200XLS Instruction Manual  

v

IMPORTANT SAFETY INSTRUCTIONS

II. During Installation

  1.  Install the gate operator on the inside of the property and fence line. 

DO NOT

 install an operator on the outside of 

the gate where the public has access to it.  

  2.  Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched.

  3.  Devices such as contact sensors (safety edges) and non contact sensors (photo beams) provide 

additional protection against entrapment. 

  4.  If push buttons or keypads are installed, they should be within sight of the gate, yet located at least 10 feet from any 

moving part of the gate (see diagram below). 

Never install any control device where a user will be tempted to 

reach through the gate to activate the gate operator. 

  5.  Do not activate your gate operator unless you can see it and can determine that its area of travel is clear of people, 

pets, or other obstructions. Watch the gate through its entire movement.

  6.  Secure outdoor or easily accessed gate operator controls in order to prohibit unauthorized use of the gate.

III. After Installation

  1.  Attach the 

warning signs

 (included)

 to each side of the gate to alert the public of auto matic gate operation. It 

is 

your responsibility 

to post warning signs on both sides of your gate. If any of these signs or warning decals 

become damaged, illegible or missing, replace them immediately. Contact LPA for free replacements.

  2.  The gate is automatic and could move at any time, posing a serious risk of entrapment.  No one should be in 

contact with an activated gate when it is moving or stationary.

  3.  Do not attempt to drive into the gate area while the gate is moving; wait until the gate comes to a complete stop.
  4.  Do not attempt to “beat the gate” (drive through) while the gate is closing. This is extremely dangerous.
  5.  Do not allow children or pets near your gate. 

Never let children operate or play with gate controls. 

Keep ALL 

gate controls away from children and unauthorized users; store controls where children and unauthorized users do 

not have access to them. 

 6. 

KEEP GATE AND GATE Operator PROPERLY MAINTAINED. 

Always turn power to operator OFF before 

performing any maintenance. Regularly grease the gate hinges.  Apply silicone spray to a soft, dry cloth and clean 

the push-pull tube at least once a month. 

Moving Gate

Area

Moving Gate

Area

Driveway

10'

10'

10'

10'

10'

10'

NEVER INSTALL

any control device

within gray area

Содержание 3000XLS

Страница 1: ...ith this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value READ ALL INSTRUCTIONS CAREFULLY AND COM...

Страница 2: ...stricted Access Vehicular Gate Operator Class IV A vehicular gate operator or system intended for use in a guarded industrial location or building such as an airport security area or other restricted...

Страница 3: ...e Bracket 10 Attach Operator 10 Install the Second Gate Operator 11 Install the Closed Position Stops 11 Mount Battery Box and Control Box 13 Connect Battery 13 Connect Operator Power Cables 15 Connec...

Страница 4: ...erators feature adjustable stall force This safety feature makes the gates stop and reverse direction within two seconds when it comes in contact with an obstruction The MIN setting means the gate wil...

Страница 5: ...s manual are identified with this warning symbol The symbol identifies conditions that can result in damage to the operator or its components serious injury or death Because GTO automatic gate operato...

Страница 6: ...alled and swings freely in both directions Repair or replace all worn or damaged gate hardware prior to installation A freely moving gate will require less force to operate and will enhance the perfor...

Страница 7: ...ach the warning signs included to each side of the gate to alert the public of auto matic gate operation It is your responsibility to post warning signs on both sides of your gate If any of these sign...

Страница 8: ...ess Systems at 3121 Hartsfield Road Tallahassee Florida 32303 or by calling 1 800 543 4283 and requesting a duplicate copy One will be provided to you free of charge Required Safety Precautions for Ga...

Страница 9: ...B A hard wired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage C A wireless contact sen...

Страница 10: ...using Conforms to UL STD 325 Certified to CSA STD C22 2 No 247 Maximum Gate 650 lb 294 8 kg 16 ft 4 9 m Voltage 12 Vdc Frequency 0 Hz Power 60 W Class I II Vehicular Swing Gate Operator 3000XLS SERIES...

Страница 11: ...nting point to mounting point arm stroke 16 max Minimum gate length is 5 ft Adjustable auto close 3 to 120 seconds and stall force potentiometers Power terminal block accommodates a transformer or sol...

Страница 12: ...battery FM123 Refer to the Solar Panel and Gate Activity chart below All low voltage wire used with the GTO Gate Operator must be 16 gauge dual conductor stranded direct burial wire RB509 Do not run m...

Страница 13: ...zontal Cross Member Vertical Cross Member Your Property Your Property Pull To Open arm retracts to open Push To Open arm extends to open 3 Prepare the Gates The gate must be plumb level and swing free...

Страница 14: ...Cable GTO Transmitter 1 RB741 Master Gate Operator 1 LPA 3000XLS Arm BRACKET BOX HB301 CONTROL BOX AND ELECTRICAL COMPONENTS HARDWARE BAG H301P Control Box 1 Receiver 1 Hairpin Clip 2 3 8 x 2 1 2 Clev...

Страница 15: ...gns 2 Second Gate Operator 1 LPA 3200XLS Arm 40 Power Cable BRACKET BOX HB301 HARDWARE BAG H301P Hairpin Clip 2 3 8 x 2 1 2 Clevis Pin 1 1 2 x 2 3 4 Bolt 2 3 8 x 3 Bolt 2 3 8 x 8 Bolt 4 8 Nylon Cable...

Страница 16: ...lts Page 11 Surge protection for transformer Page 18 Weatherproof cover for transformer if installed outside Page 18 For push to open applications you must have two 2 PTO Brackets R4388 Drill Bit Dril...

Страница 17: ...necessary to use hex head bolts longer than those supplied Round wood posts no smaller than 8 diameter may be notched to create a flat surface for attaching the post bracket Wood posts will require a...

Страница 18: ...he position of post bracket holes on the post Step 3 Drill holes through post as marked using a 3 8 drill bit Install the post bracket using the 3 8 x 8 hex head bolts and 3 8 flat washers lock washer...

Страница 19: ...est part of the operator arm and the gate When you have achieved the best position for the post pivot bracket in the open position insert the 3 8 x 3 bolt and 3 8 flat washer through the aligned holes...

Страница 20: ...ke sure the gate bracket is clamped securely Install Gate Bracket Step 9 Detach the front mount from the gate bracket Check that the gate bracket holes are centered over the scribe line Mark the gate...

Страница 21: ...OND Gate Frame MASTER Gate Frame TOP VIEW FRONT VIEW Step 1 Detach the gate operators from the gates and move the gates to their closed position Illustration A Using appropriate hardware for your type...

Страница 22: ...plate The ground stop needs to be positioned near the end of the gate as shown in Illustration A and may be made of metal or concrete and should be firmly secured in the ground we recommend setting i...

Страница 23: ...he KNOCK OUT in the back of the CONTROL BOX Plug the BATTERY HARNESS wires into the wires coming from the CONTROL BOX Connecting the Battery Step 3 Slide the battery into position with the terminals t...

Страница 24: ...rent locations before permanently mounting the receiver The receiver range can vary from 50 to 100 feet depending upon weather topography and external interference Mount the receiver Ensuring a line o...

Страница 25: ...Cut a slot into the driveway to accommodate 3 4 PVC conduit not provided The buried conduit will protect the SECOND operator power cable from automobile tires lawn mower blades weed eaters and grazin...

Страница 26: ...GRN terminal the white wire into WHT the blue wire into BLUE brown wire into BRN orange wire into ORG red wire into RED and the black wire into the BLK terminal Tighten the set screws against the end...

Страница 27: ...rom an AC power source you will need to use at least 10 watts solar charging power FM122 FM123 to charge the battery Refer to the Solar Panels and Gate Activity Chart on page 2 Step 1 Make sure the co...

Страница 28: ...screws against exposed end of wires Step 6 At the transformer strip 1 2 of insulation from the ends of the low voltage wire Twist tightly and attach wires to the transformer terminals Make sure the ex...

Страница 29: ...old LEARN MAST LIMIT for 5 seconds or until buzzer beeps to set closed postion B If the second gate reaches closed postion first press and hold LEARN 2ND LIMIT for 5 seconds or until buzzer beeps to s...

Страница 30: ...w programmed Control Box Learn Master Limit Button 1 2 3 4 ON DIP STATUS LEARN RMT LEARN MAST LIMIT LEARN 2ND LIMIT S3 S4 S2 SOFT START OFF WARNING OFF OPEN PULL SLV OPEN DLY MODE1 OFF MODE2 OFF ON ON...

Страница 31: ...to increase the stall force in cold temperatures due to increased resistance from gate hinges Set Auto Close Time The Auto Close Time potentiometer controls the Auto Close feature and determines how...

Страница 32: ...close the access cover WARNING No other adjustments should be made inside the transmitter Step 3 Program the new setting into the control board A Press and hold transmitter button B Press and hold th...

Страница 33: ...the obstruction warning DIP Switch 3 Push Pull to Open ON Push to open OFF Pull to open factory preset If your gate opens into the property the DIP Switch is set to the OFF position factory setting I...

Страница 34: ...this input while at open limit will restart the auto close time if enabled Activation of this input while gate is idle will prevent gate from closing 5 SHADOW LOOP Typically for use with loop detecto...

Страница 35: ...ONTROL INPUTS CLOSE EDGE 2 3 4 5 6 7 WHT BLU BRN ORG RED BLK GRN WHT BLU BRN ORG RED BLK GRN COM CYCLE COM LOCK PWR AUX RLY POWER INPUT CONTROL OUTPUTS MASTER OPERATOR 2ND OPERATOR CONTROL INPUTS GTO...

Страница 36: ...sh to Open Post Pivot Bracket R4388 in the Post Bracket assembly B 4 IMPORTANT While determining the mounting point for the post pivot bracket assembly be sure that the position allows for 2 clearance...

Страница 37: ...Box Master Gate Operator Second Gate Operator Step 2 Press the transmitter to activate operator arms The gates will begin to open Gates Opening Control Box Step 3 When either gate reaches OPEN positi...

Страница 38: ...tivate operator arms The gates will begin to OPEN Step 6 The gate that was programmed in step 4 will stop on its own Press the transmitter again to stop the other gate when it reaches the desired OPEN...

Страница 39: ...Counter 1 beep with 10 seconds off Low Battery Condition Fuses Battery Harness Connections Battery Under Load 1 beep then 2 beeps Master Motor Terminals Shorted Connections to Master Inputs Master Ar...

Страница 40: ...accessory Status clear 5 blinks Close Edge Terminal Shorted Disconnect the edge sensor photo beam or any other accessory wired to this terminal Try the remote If the remote works the problem is the ac...

Страница 41: ...ired to send in your original equipment for repair Please refer to Manufactures Limited Warranty for complete details Securely pack the component s authorized for return to the factory Include a copy...

Страница 42: ...B741 RB742 RB743 Purchase an additional transmitter for each vehicle in your family The Two Button Transmitter can be programmed to operate both your gate operator and a garage door opener using the U...

Страница 43: ...property 100 ft range between transmitter and receiver Easy installation LOCKING SECURITY ACCESSORIES Automatic Gate Lock FM144 FM142 The 1 Accessory For Swing Gate Operators Designed for added securi...

Страница 44: ...rge Gate Grounding Kit R4196 The purpose of the grounding kit is to REDUCE THE RISK of damage to electronic equipment from lightning strikes There is no protection or grounding system that can complet...

Отзывы: