28
LPA 3000XLS/3200XLS Instruction Manual
If this operator will be used with gates that are mounted on masonry, brick, or rock (etc.) columns, read
the following carefully before proceeding
A. The simplest solution is to install the operator in a push-to-open configuration. The minimum
clearance is easier to achieve and clearance is no longer a problem, since the operator will be
pushing the gate away from the column instead of pulling it toward the column. It is recommended
that you place a steel plate between the operator mounting brackets and masonry surface for
additional strength.
B. If a push-to-open installation is impossible
due to traffic hazards, terrain, etc., another
option is to re-hang the gate. You may
hang it on a post, either in the center of the
column or at the back corner, or move the
gate to the back corner of the columns.
C. The most difficult solution is to cut a notch
in the column to accommodate the operator
and power cable. This job is NOT for the inexperienced!*
Column Installation
Column
Pivot Bracket
Gate
A
B
Column Mount Example
(A + B can not exceed 16 inches)
Example: If A is 7" then B cannot exceed 9"
Hinge
*The Troubleshooting Wizard has detailed information on column mounting.
Gates
Opening
Control
Box
Master
Gate
Operator
Second
Gate
Operator
Step 5
Press the transmitter to activate
operator arms. The gates will
begin to OPEN.
Step 6
The gate that was programmed in step 4
will stop on its own. Press the transmitter
again to stop the other gate when it
reaches the desired OPEN limit.
A1. Master gate reaches open postion -
press and hold LEARN MAST LIMIT for
5 seconds, or until buzzer beeps to
set open postion. (Master gate is now
programmed)
B1. 2nd gate reaches open postion -
press and hold LEARN 2ND LIMIT for
5 seconds, or until buzzer beeps to
set open postion. (Second gate is now
programmed)
Step 7
Press the transmitter once again to close gates. Both gates open position are now programmed.
If you make a mistake and set the limit at the wrong position: press your transmitter to return the gates
to the fully closed position, then press and hold the LEARN MAST LIMIT and/or the LEARN 2ND LIMIT
button for 5 seconds. This will clear the memory for the open limit position. Repeat Steps 1-6
Learn Master
Limit Button
1 2 3 4
ON
DIP
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
2ND LIMIT
S3
S4
S2
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
MAX
AUTO CLOSE TIME
STALL FORCE
Learn 2ND
Limit Button
Learn Master
Limit Button
1 2 3 4
ON
DIP
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
2ND LIMIT
S3
S4
S2
SOFT START OFF
WARNING OFF
OPEN PULL
SLV OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN
MAX
AUTO CLOSE TIME
STALL FORCE
Learn 2ND
Limit Button
A
.
B
.
2nd Gate B1
Opening
Follow A1 directions to
program master gate
open position.