LPA 3000XLS/3200XLS Instruction Manual
11
Install the Second Gate Operator
(3200XLS)
The hardware installation for the 3200XLS is the same as the 3000XLS - follow Steps 1
to 10 on pages 8 - 10 to install the 3200XLS on the second gate.
Closed Position
Stop Plates
Gate Hinge
Control
Box
Gate Hinge
The gate leaf can open
up to 110˚ (max.)
Optional Ground Stop
(beneath gate)
The gate leaf can open
up to 110˚ (max.)
MASTER GATE
SECOND GATE
The 3000XLS/3200XLS Gate Operators firmly hold the gates in the closed position using positive
stops. The positive stops help stabilize the gate leaves in the closed position. To further enhance
stability and security, we strongly recommended using an optional GTO Automatic Gate Lock.
Illustration A
Closed Position Stop Plate mounted
horizontally on metal post with U-bolts.
SECOND
Gate Frame
MASTER
Gate Frame
TOP VIEW
FRONT VIEW
Step 1
Detach the gate operators from the gates
and move the gates to their closed position
(Illustration A). Using appropriate hardware
for your type of gate (U-bolts for tube or chain
link; screws or bolts for wood or metal) attach
the closed position stop plate (horizontally) in
line with the operator arm, about mid height
on the MASTER gate frame. Do not tighten it
completely at this time. Slide the stop plate
toward the frame of the SECOND gate leaf
until they touch (Illustration B). Once you have
moved the stop plate to the correct position,
tighten its hardware completely.
Illustration B
IMPORTANT:
The gate and gate
operator on the same side as the
control box will be referred to as
the MASTER gate and gate operator.
The gate and gate operator on the
opposite side of the driveway from
the control box will be referred to as
the SECOND gate and gate operator.
Note: Ground stop required for
GTO automatic gate lock.
Install the Closed Position Stops