Motor – Specifications
Always use the motor with required horse power as suggested in the following charts.
Maximum 8 in. Lengths (Feet)
Required HP
Degree of Incline
Horizontal
15
30
45
60
5
62
39
27
21
19
10
121
80
55
42
38
15
184
119
82
62
57
20
250
158
109
83
76
25
313
198
136
103
95
Maximum 10 in. Lengths (Feet)
Required HP
Degree of Incline
Horizontal
15
30
45
60
10
82
54
36
28
25
15
125
83
55
42
39
20
168
108
74
56
52
25
210
136
92
70
65
30
255
162
112
85
78
Recommended Motor Overload Protection
To protect the gearbox and motor from extreme overload situations, follow the below chart when sizing the
electrical circuit for the VersaLoop™. The circuit breakers should be sized based on the below charts and
appropriate electrical codes.
Required HP
Max Motor Amperage Rating
Three phase 60Hz
Single phase 60Hz
Three phase 50Hz
208V
230V
460V
575V
230V
240V/380V – 415V
5
14A
14A
7A
6A
28A
8.7A
10
26A
26A
12A
11A
50A
14.4A
15
40A
37A
19A
17A
68A
21A
20
–
50A
25A
22A
–
28.5A
25
–
60A
30A
27A
–
34A
30
–
74A
37A
32A
–
41A
12
Pneg-1966
VersaLoop™
Содержание VersaLoop
Страница 1: ...VersaLoop Models Owner s Manual PNEG 1966 Version 1 0 Date 11 05 14 PNEG 1966...
Страница 2: ...2 Pneg 1966 VersaLoop...
Страница 4: ...NOTES 4 Pneg 1966 VersaLoop...
Страница 14: ...NOTES 14 Pneg 1966 VersaLoop...
Страница 26: ...NOTES 26 Pneg 1966 VersaLoop...
Страница 32: ...NOTES 32 Pneg 1966 VersaLoop...
Страница 50: ...NOTES 50 Pneg 1966 VersaLoop...