Troubleshooting
57 | 76
BA_TD
3-
BS
00
0en
_07
4_sof
tli
Q
-S
C
.docx
Display
Explanation
Remedy
Regeneration water meter
defective!
Regeneration water
meter is not emitting
pulses.
Connecting cable
defective.
Water supply
interrupted.
Check water supply.
Notify Grünbeck's technical service/
authorised service company.
System is not drawing brine
from the brine tank effectively
enough!
Minimum contact during
salting not reached.
Monitoring time
exceeded.
Injector clogged or raw
water pressure too low.
Notify Grünbeck's technical service/
authorised service company.
Nominal flow rate exceeded!
Only displayed if
monitoring was
activated by the
specialist installer.
System is being
operated with excessive
flow rates.
Reduce peak flow.
If the error persists, notify Grünbeck's
technical service/ authorised service
company.
9.2
Other observations
Observation
Meaning
Remedy
No soft water
Excessive water
consumption
(water softener has
exceeded its capacity).
Restrict your water consumption to
the maximum flow rate permitted
(refer to chapter 12).
Perform a manual regeneration (refer
to chapter 7.2).
Water softener does not
have a permanent
power connection.
Check the mains connection.
Soft water meter is not
emitting pulses.
Notify Grünbeck's technical service/
authorised service company.
Raw water hardness set
too low.
Measure the raw water hardness
(refer to chapter 7.4).
Check the value in the control unit
(refer to chapter 7.6).
Incorrect setting of
blending valve
Readjust the blending valve
(refer to chapter 7.7).