Installation
33 | 76
BA_TD
3-
BS
00
0en
_07
4_sof
tli
Q
-S
C
.docx
NOTE:
The valves of the system are operated electrically.
● Water can flow to the drain unchecked if there is a power failure during
regeneration.
► If there is a power failure, check your product and shut off the water supply, if
necessary.
NOTE:
Malfunction of the lifting system if there is a power failure.
● Water damage in case the lifting system fails
► Secure your water installation against inadvertent water leakage if there is a
power failure.
The installation room must be provided with a floor drain. If no floor drain is available, an
appropriate safety device has to be installed to prevent water damage. We recommend
using a protectliQ safety device (refer to chapter 3.7).
If the softened water is intended for human consumption in the sense of the German
Drinking Water Ordinance, the ambient temperature must not exceed 25 °C. For applications
that are purely technical, the ambient temperature must not exceed 40 °C.
Downstream of the system, a withdrawal point for cold water must be available in close
proximity.
NOTE:
Functional failure if lifting systems are not resistant to salt water.
● Water damage in case the lifting system fails
► Use a salt water-resistant lifting system or our regeneration water delivery pump
(refer to chapter 3.7).