Operation
49 | 76
BA_TD
3-
BS
00
0en
_07
4_sof
tli
Q
-S
C
.docx
7.5.1
Setting the current time
Setting the time is only required and possible if you have selected the "fixed" time of
regeneration.
Status level>Menu level>Settings>Select time of regeneration>Set
current time
1.
Press ENTER.
2.
Use ▲ and ▼ to set the time.
3.
Confirm with ENTER.
7.5.2
Setting the time of the fixed regeneration
Status level>Menu level>Settings>Select time of regeneration>Set
time of regeneration
1.
Press ENTER.
2.
Use ▲ and ▼ to set the time.
3.
Confirm with ENTER.
7.6
Entering the raw water hardness
Status level>Menu level>Raw water hardness
1.
Press and hold the ▼ and ▲ buttons for 2 seconds.
2.
Enter the value with ▼ and ▲.
3.
Confirm with ENTER.
7.7
Setting the blending valve
The blending valve may only be adjusted while the water is running (approx. 400 – 600 l/h,
which is about the flow rate of a fully opened water tap).
1.
Measure the raw water hardness (refer to chapter 7.4).
2.
Move the blending valve to the middle position.
3.
Measure the soft water hardness (refer to chapter 7.4).
4.
Set the soft water hardness to the required value (3 - 6 °dH (5…11 °f) is
recommended).