Troubleshooting
56 | 76
BA_TD
3-
BS
00
0en
_07
4_sof
tli
Q
-S
C
.docx
9.1.2
Fault signals (red symbols)
Display
Explanation
Remedy
Power failure > 5 minutes
Only displayed if
detection is activated.
Upon return of power,
the water softener will
perform a regeneration.
If there is a power
failure, any regeneration
in progress at the time is
stopped and then
continued afterwards.
Check the mains connection.
Reset the clock of the water softener
if there is a power failure > 3 days
(only with the "fixed" time of
regeneration, refer to chapter 7.5.1).
Trigger a manual regeneration
(refer to chapter 7.2).
Salt supply used up!
Refill immediately!
(Order no. 127 100)
Salt supply used up.
Refill salt tablets (refer to
chapter 7.8), acknowledge the
malfunction with ENTER.
Hollow area below the
salt.
Break up incrustations with a suitable
tool.
Water pressure too low.
Increase flow pressure to at least 2.0
bar.
Chlorine cell worn.
Brine filling orifice,
injector, injector sieve or
brine valve clogged.
Notify Grünbeck's technical service/
authorised service company.
Malfunction at the drive
of the regeneration control valve!
Step monitoring of
regeneration motor or
connecting cable
defective.
Notify Grünbeck's technical service/
authorised service company.
Regeneration water meter
Volume not reached!
Regeneration water
meter is not emitting
pulses.
Connecting cable
defective.
Water supply
interrupted.
Check water supply.
Notify Grünbeck's technical service/
authorised service company.
Soft water meter defective!
Soft water meter is not
emitting pulses.
Connecting cable
defective.
Water supply
interrupted.
Check water supply.
Notify Grünbeck's technical service/
authorised service company.