SPECIFICATIONS • VRC-3E, VRC-6E
Electrical Supply Connection
Observe all local, national, or other applicable codes.
Three phase models of the Vortex
®
Connectionless Steamer are
supplied with a cord set ready to be connected to a power supply.
See the chart below for the correct matching receptacle (not
supplied with the unit).
Single phase models are designed to be directly connected (hard
wired) to the electrical supply and allow sufficient loop in the
flexible conduit to facilitate inspection, servicing, and cleaning.
Brach Circuit Protection
Each Steamer, including individual units of stacked models,
should have its own branch circuit protection and ground wire.
Current and power demands for each unit are as shown below.
Field Wiring Table
Use copper wire only – insulation rating 90°C
Voltage
KW
Rated Current
60 hz only
Demand (amps)
VRC-3E
VRC-6E
VRC-3E
VRC-6E
208, 3 phase
9
12
25
34
240, 3 phase
9
12
22
29
480, 3 phase
9
12
11
25
WARNING
GROUNDING INSTRUCTIONS:
This appliance must be connected
to a grounded metallic, permanent
wiring system, or an equipment
grounding conductor must be run
with the circuit conductors and
connected to the equipment
grounding terminal on the station.
Plug & Receptacle Chart
Three Phase Only
Volts Phase
Plug
Receptacle
9 KW
12 KW
9 KW
12 KW
208
3
15-50P
15-50P
15-50R
15-50R
240
3
15-30P
15-50P
15-30R
15-50R
480
3
L16-20P
CS8165C
L16-20R
CS8169
Hubbel or
Hubbel or
Equivalent
Equivalent