1
Call 1-800/676-9040 for Technical Support
2
INTRODUCTION
WARNING:
The signal word
WARNING
tells you that a
possibly hazardous situation is about to take place which, if not
avoided, could cause death or serious injury.
• Always turn off the steamer power before removing
and partitions or panels.
• Disconnect the steamer from the power source before
performing and internal service work.
CAUTION:
The signal word
CAUTION
warns you of a
hazardous situation which, if not avoided, may result in minor
or moderate injury.
• Steamer may be hot. Take precautions to prevent any contact
with hot surfaces.
• Be sure all interior partitions have been installed before
operating the steamer.
• All steamer operators and service personnel should be
familiar with correct and safe operating procedures.
• Be sure steamer drain is not blocked as this could result in
improper steamer operations.
Two other signal words, not directly related to personal safety,
are also used in this manual:
NOTICE
and
IMPORTANT.
NOTICE
is used to alert you to hazards that may result in
component and/or equipment damage.
IMPORTANT
is used to highlight an operating or maintenance
tip or suggestion.
1.5 Glossary of Terms
The following abbreviations and terms are used in this manual:
BTU
British Thermal Unit
GPM
Gallons Per Minute
LED
Lighting Emitting Diode
MM
Millimeter
NEC
National Electric Code
N.P.T.
National Pipe Thread
NSF
National Sanitation Foundation
PSI
Pounds per Square Inch (Pressure)
U.L.
Underwriter’s Laboratory, Inc.
1.6 Tools and Supplies
This Section identifies the tools, instruments and supplies which
will be required and useful in the inspection, repair and testing
of the equipment described in this manual.
Most likely many of these tools and supplies are already in your
tool kits and are used in everyday maintenance. Make sure to
use only the specified sealants, compounds and dressings.
CAUTION:
Care should be taken in using the correct tool as
indicated. Using the wrong tool may inflict damage to the part
being removed, installed and/or adjusted. Make sure that the
calibrations on instruments are periodically checked for accuracy.
1.6.1 Required Tools
• Screw Drivers: Flat Blade No. 1 and No. 2
• Phillips No. 1 and No. 2
• Socket Wrenches: 1/4” through 7/8” (Magnetic)
• Nutdrivers (metric and inches)
• Open Ended Wrenches: 1/4” through 7/8”
• Pipe Wrenches: 6” and 8” size
• Allen Wrenches: 1/16” through 1/4”
• Slip Joint Pliers: ChannelLock or Equivalent
• Wire Crimpers
1.6.2 Recommended Instruments
• Digital Multimeter: Fluke Model 77
1.6.3 Helpful Hardware
• Extension Mirror
• Screw Starter
• Level: 18” Model
• Fuse Puller