5
Call 1-800/676-9040 for Technical Support
4
TROUBLESHOOTING
AMPERAGE / RESISTANCE CHART
Model / Voltage / Phase*
Amperage
Resistance
VRC-6E
208 Three Phase
33.3
10.5
VRC-6E
240 Three Phase
28.8
14.5
VRC-6E
480** Three Phase
14.4
19.5
VRC-6E
208 Single Phase
57.7
10.5
VRC-6E
240 Single Phase
50
14.4
VRC-3E
208 Three Phase
25
14.5
VRC-3E
240 Three Phase
21.7
19.5
VRC-3E
480 Three Phase
10.8
77
VRC-3E
208 Single Phase
43.2
14.5
VRC-3E
240 Single Phase
37.5
19.5
*Special units use VRC-6E elements in a VRC-3E and vice versa
** The voltage applied to the unit is 480, but the elements are wired so each operates on 277VAC
HOLD RESISTOR CHART
Hold
Resistance
Temperature
in K ohms
150
28.7
160
46.4
170
68.1
180
100
190
140
200
200