Call 1-800/676-9040 for Technical Support
5
5.1 Air Temperature Probe
Removal
1. Turn off the steamer power and disconnect the steamer
from the branch circuit.
Note:
an incorrectly installed air
temperature probe MUST be replaced. Trying to operate the
steamer with a bent or crushed probe will result in improper
steamer operation.
2. Check to make sure the air temperature probe is not bent or
crushed and is installed through the opening in the probe
mounting bracket. There must be a 1/8” to 1/4" air gap
between the probe tip and the probe mounting bracket.
If the probe is bent, it must be replaced. If the probe tip
location is not within the 1/8" to 1/4" air gap required,
remove the air probe and correctly re-install it.
3. Remove the right and left covers from the steamer.
4. Disconnect the air temperature probe electrical leads from
the probe harness.
5. Loosen the probe compression nut.
6. Remove the air temperature probe. Note: Slide probe
through hole in rear cover to remove. lf the male fitting was
removed with the probe and compression nut, remove it
from the probe. The probe and compression nut are an
assembly.
Installation
7. If the air probe guard is not in place, one will have to be
installed. Order all of the component parts required using
the illustration shown.
8. lf a new guard assembly is being installed, install the guard
assembly, air temperature probe fitting, fiber washer,
stainless steel washer, and nut as shown in the illustration.
9. Install the new air probe and compression nut assembly.
Be careful not to bend the probe as you insert it through
the steamer wall and on through both ends of the
mounting bracket.
10. Connect the probe wires to the harness.
11. Replace the back, left and right covers.
12. Connect the steamer to the branch circuit.
13. Turn on the steamer power and test the steamer.
ASSEMBLY / DISASSEMBLY
WARNING
Be sure the steamer is disconnected from the branch circuit power
before performing any repair work.