5
Call 1-800/676-9040 for Technical Support
6
ASSEMBLY / DISASSEMBLY
Installation
12. Assemble the plate assembly DRY to be sure the orientation
of the assembly is correct and the correct sides of the plates
are marked. There is not enough paste supplied with the kit
to do the assembly twice. Disassemble to apply the Thermal
Paste.
13. Apply the Thermal Paste evenly to the bottom of the cavity
or top of upper aluminum heat sink plate. See the figure on
page 5-17. Thickness should be about 1/4” inch. Place the
upper heat sink plate in place on the bottom of the cavity.
14. Spread the Thermal Paste over both sides of the element.
It is easiest if disposable gloves are used.
15. Carefully place the element on the upper aluminum plate.
Ensure correct orientation of he element.
16. Place the lower aluminum heat sink plate on the element.
This plate has orientation studs.
17. Place the press plate on the lower heat sink plate.
18. Re-install the support brackets and insulation.
19. Enclose the assembly with the plate support cover.
20. Reinsert the drain lever and check for orientation.
21. Wire elements per wiring diagram. Note: 6-pan 480v
3 phased must be wired in a Y-configuration.
5.13 Hi-limit Thermostat - P/N 141661
The thermostat is attached to the center heater support bracket,
and is held on with two 6-32 x 3/8” long screws.
Removal
1. Turn off the steamer power and disconnect the steamer
from the branch circuit.
2. Unplug the two wires from the thermostat to the wiring
harness.
3. Using a short flat blade screwdriver, remove the two 6-32
screws holding the thermostat to the heater support bracket.
Installation
4. Seat the thermostat on the heater support bracket and
fasten with the two screws.
5. Plug the two wires from the thermostat into the wiring harness.
5.14 Leg Assemblies - P/N 43121
The leg assemblies are screwed into weld nuts attached to the
base assembly.
Removal
1. Turn off the steamer power and disconnect the steamer
from the branch circuit.
2. Raise the steamer up and support the weight of the steamer
3. Unscrew the leg assembly
Installation
4. Line up the threaded stud on the leg assembly with the weld
nut attached to the base, and screw the leg in until tight
5. Lower the steamer onto all four legs
6. Check the level of the steamer