Call 1-800/676-9040 for Technical Support
5
5.5 Door Switch - P/N 096857
Removal
1. Turn off the steamer power and disconnect the steamer
from the branch circuit.
2. Remove the right side cover from the steamer.
3. Disconnect the door switch harness from the control board.
4. The switch is held in place by two slotted screws. Removing
these two screws will allow the removal of the switch.
5. If the door has been reversed, remove the left side cover
and follow the instructions above.
Installation
6. Secure the new switch with the two slotted screws.
7. Plug in the door switch harness into the control board.
8. Replace the side cover.
9. Reconnect the branch circuit power supply.
10. Turn “ON” the steamer and test for proper operation.
5.6 Door Reversing Procedure
1. Turn OFF the power to the steamer.
2. Support the door while removing the hinge-to-steamer
bolts.
3. Place the door, with the hinge on a flat clean table, and the
gasket face up.
4. Note the distance between the lock nut and the end of the
door-locking pin (bullet). This information will be needed
later on in step 6.
5. Loosen the lock nut, and then remove the door bullet and
lock nut.
6. Coat the bullet threads with a few drops of Locktite 242.
Install the bullet and lock nut directly across the steamer
cavity from the old bullet location. Install these two items
so that the lock nut to end of the bullet distance is
approximately the same as measured in step 4.
7. Remove the two screws from above and below the old
bullet location and install them above and below the new
bullet location.
8. Remove the screws and U-channel from the door. Take the
magnet and block assembly from the present location and
place it at the opposite end of the door channel, with the
magnet facing outward from the door.
9. Remove the two screws holding the door handle and cam.
10. Apply NEVER-SEEZ high temperature (1800 degree F)
anti-seize and. lubrication compound to the cam and a few
drops of Locktite 242 to the door handle screw threads.
11. Turn the handle and cam 180-degrees from their original
position and install them on the door with the screws. Be
sure the handle and can move smoothly.
12. Be sure the door handle and door cam are in the DOWN
position. Turn the U-channel 180-degrees from, its original
position, hold the door spring in the U-channel open with a
screw driver or similar tool, and install the U-channel being
sure the door spring is seated over the cam.
13. Check the operation of the cam. Push UP on the door handle
and check if the spring opens. If the spring does not open,
the cam and spring are NOT correctly aligned and the
problem must be corrected.
14. Apply a light amount of Locktite 242 to the screws, then
install them to hold the U-channel in place.
15. Apply Locktite 242 to the hinge-to-steamer bolts, and then
install the door and hinge mounting bolts. Do NOT tighten
the mounting bolts at this time.
16. Align the door to the steamer as described in the
“Alignment Procedure” page 5-7.
17. Replace the right side cover.
18. Turn on the power to the steamer.
19. Close the steamer door and operate the steamer. If the fan
does not operate, check the location of the door magnet
and be sure the alternative door switch was connected.
23. With the door closed and the steamer in the “ON” position,
or the timer running, the “READY” light should come on in
15 to 20 minutes.
24. Once the steamer is up to “READY” check for leaks. If there
are no leaks then the steamer is ready for operation. If there
are leaks, recheck the door alignment and gasket installation.
5.7 Door Gasket
P/N 124849 VRC-3E
P/N 140748 VRC-6E
Removal
1. Turn OFF the steamer and allow to cool.
2. Remove the door following the procedure for “Door Removal”.
3. Position the door on a clean flat surface.
4. Remove the inner door panel, using a flat blade screwdriver,
and remove the screws.
5. Remove and discard the old gasket.
6. Clean the back of the inner door panel and remove all of
the old sealant.
ASSEMBLY / DISASSEMBLY
Содержание Vortex VRC-3E
Страница 1: ...Atmospheric Connectionless Steamers SERVICE MANUAL Models VRC 3E VRC 6E...
Страница 9: ......
Страница 15: ...Call 1 800 676 9040 for Technical Support INSTALLING CLEANING AND TESTING Notes...
Страница 45: ......
Страница 57: ......