5
Call 1-800/676-9040 for Technical Support
8
ASSEMBLY / DISASSEMBLY
5.17 Motor Starting Capacitor - P/N096813
Removal
1. Turn off the steamer power and disconnect the steamer
from the branch circuit.
2. Loosen the two screws holding the motor capacitor.
3. Loosen the rubber boot from the capacitor and pull the boot
clear of the wire terminals.
4. Unplug the two wires from the capacitor. Remove the
capacitor.
Installation
5. Install and tighten the two screws holding the capacitor to
the mounting plate.
6. Plug in the terminal wires to the capacitor, and slide the
rubber boot over the wire terminals.
7. Re-connect the branch circuit power and test the steamer
for proper operation.
5.18 Back Panel
P/N 140444 Back Panel VRC-3E
P/N 140764 Back Panel VRC-6E
Removal
1. Turn off the steamer power and disconnect the steamer
from the branch circuit.
2. Remove the right, left and top panels (as described in Items 5).
3. Then remove the single 10-32 screw holding the cavity vent
to the back panel and the two screws at the bottom of the
panel.
4. Support the electrical control assembly that is attached to
the back panel.
Installation
5. Hold the back panel in-place and replace the two 10-32
screws on the bottom edge of the panel.
6. Re-attach the cavity vent assembly with the single 10-32
screw.
7. Replace the top, left and right side panels.
8. Turn on the electrical power the steamer.
5.19 Right Side Panel and Left Side Panel
P/N 140447 Right Side Panel VRC-3E
P/N 140448 Left Side Panel VRC-3E
P/N 140761 Right Side Panel VRC-6E
P/N 140762 Left Side Panel VRC-6E
Removal
1. Turn off the steamer power and disconnect the steamer
from the branch circuit.
2. With a flat blade screwdriver remove the three 10-32
screws, two on the bottom edge and one on the top edge.
The panel is retained to the front edge of the steamer by a
tongue and groove and by a spring-like clamp on the back
and bottom edges.
3. Once the screws are removed slide the panel towards the
front with a lifting motion. Do not attempt to pry the panel.
Once the panel is free of the rear clips, the panel may be
lifted off.
Installation
4. When replacing the panel, press the rear edge inward so
that all of the spring-like clip will be retain the rear flange.
5. Make sure that the holes in the panel are in alignment with
the tapped holes in the steamer so that the replacement on
the screws will be easy and not damage the screws.
5.20 Top Panel
P/N 140760 Top Cover VRC-3E
P/N 123133 Top Cover VRC-6E
Removal
1. Turn off the steamer power and disconnect the steamer
from the branch circuit.
2. First remove the right and left side panels (as described in
item 5).
3. Remove the retaining bracket, which prevents the top from
sliding forward.
4. Slid the cover forward, and once clear of the spring-like clips
on the back and the front flange, the cover may be lifted off.
Installation
5. Hold down the center rear to engage the sprig-like clips and
slid the cover over the front flange.
6. Replace the two retaining brackets.
Содержание Vortex VRC-3E
Страница 1: ...Atmospheric Connectionless Steamers SERVICE MANUAL Models VRC 3E VRC 6E...
Страница 9: ......
Страница 15: ...Call 1 800 676 9040 for Technical Support INSTALLING CLEANING AND TESTING Notes...
Страница 45: ......
Страница 57: ......