Model G0819 (Mfd. Since 09/16)
-21-
1. Unlatch and open electrical panel access
door (see
Figure 23).
2. Insert incoming power wires where strain
relief is located on cabinet next to electrical
panel access door (see
Figure 23).
During next step, make sure incoming
ground wire is connected to right-most ter-
minal (see "Ground Terminal" in Figure 24 to
ensure machine will be properly grounded).
An ungrounded or improperly grounded
machine could cause electrocution if live
electrical wires make contact with the frame
or other parts touched by the operator.
3. Connect ground wire to bottom of ground
terminal
E, then connect incoming power
wires to bottom
R and S terminals shown in
Figure 24.
Figure 24. Terminal locations to connect
incoming power wires and ground wire.
Incoming Power
Terminals
Ground
Terminal
Connecting Power Supply Wires
Figure 25. Connecting power to machine.
Move the disconnect switch handle to the ON
position, as illustrated below. The machine is now
connected to the power source.
Connecting to Power Source
Figure 26. Disconnecting power from machine.
Move the disconnect switch handle to the OFF
position, as illustrated below. The machine is now
disconnected from the power source.
Note: Lock the switch in the OFF position to
restrict others from starting the machine.
Disconnecting from Power Source
4. Make sure wires have enough slack inside
eletrical panel so they are not pulled tight or
stretched.
5. Close and secure electrical panel door, then
perform
Test Run.
Figure 23. Location of electrical panel and strain
relief.
Strain Relief
Electrical
Panel
Access
Door
Содержание G0819
Страница 84: ......