-28-
Model G0806/G0807 (Mfd. Since 12/15)
Test Run
Once assembly is complete, test run the machine
to ensure it is properly connected to power and
safety components are functioning correctly.
If you find an unusual problem during the test run,
immediately stop the machine, disconnect it from
power, and fix the problem BEFORE operating the
machine again. The
Troubleshooting table in the
SERVICE section of this manual can help.
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine
may result in malfunction or unexpect-
ed results that can lead to serious injury,
death, or machine/property damage.
Serious injury or death can result from
using this machine BEFORE understanding
its controls and related safety information.
DO NOT operate, or allow others to operate,
machine until the information is understood.
To test run the machine:
1. Make sure the blade is properly tensioned
and tracked (refer to
Tensioning & Tracking
Blade on Page 23) and the blade guides
are positioned correctly (refer to
Adjusting
Blade Guide Assemblies on Page 25).
2. Clear all setup tools away from machine.
3. Connect the machine to the power source.
4. Push the ON button (see Figure 33). The
green motor light will illuminate and the motor
will start.
6. Adjust the blade speed through the full
range of operation using the variable speed
handwheel (see
Figure 33). The speed
should change as you make the adjustments.
5. Verify that the machine is operating correctly.
When operating correctly, the machine runs
smoothly with little or no vibration or rubbing
noises.
Содержание G0806
Страница 80: ......