English
35
7.1 Lamp specifications
Graphite MK2 2000
is designed to be used exclusively with Philips MSD Platinum 15R lamp.
The lamps are part of the mercury vapour family of discharge lamps and must be handled with great care. The
lamp operates at high pressure, and the slight risk of explosion of the lamp exists if operated over its recommended
life. We recommend, therefore, that the lamp is replaced within the manufacturer’s specified lamp life.
The projector’s display will show an alarm once 1900 hours of lamp life are exceeded and, in case tha lamp is not
replaced within 2100 hours, the projector will not turn on.
Every time the lamp is replaced, please reset the lam-
plife counter
, as described in paragraph 12.3, in order to determine when to perform the next replacement.
The specification of the lamp, available via the Griven network of dealers and distributors, are shown in the table
below.
7.2 Using the yoke “Aiming Lock System”
If the location of the projector does not allow the opening of the rear ballast, it is possible to replace the lamp
without modifying the projector’s pointing.
A.
Untighten the screw
“20”
.
7.0 Lamp installation and replacement
Attention!
Installing any other lamp may create a safety hazard or damage the fixture!
Lamp
PHILIPS MSD Platinum 15R
Griven code
LP1032
Rated lamp wattage
300W
Colour temperature
8000K
Luminous flux
13500lm
Average service life
2000h
CRI
75
90° 80°
70
Warning:
Unscrew for lamp
replacement only.
20
Warning!
While undoing the screws “20”, please hold up the
projector in order to avoid that it suddenly inclines.