12.1 Manual ignition of the lamp
The lamp can be turned on manually (without DMX control) using the function "MAN" in the menu lamp man-
agement "LMP".
Press the "MENU" button until you see "ADR". Press "UP" or "DOWN" until "LMP". Press "UP" or "DOWN" until "MAN".
Press "ENTER" and scroll through the options "ON" or "OFF". Press "ENTER" to confirm.
If the function is set to OFF, the lamp will be lit ONLY via DMX signal.
If the function is set to ON, the lamp will remain switched ON.
12.2 Visualization of the lamp life
The projector is equipped with a timer for lamp life.
Press the "MENU" button until you see "ADR". Press "UP" or "DOWN" until "LMP". Press "UP" or "DOWN" until "LLF". Press
"ENTER" to confirm. The lamp utilization (expressed in hours) since last reset will be displayed.
The lamp has an average life of 2,000 hours.
The projector’s display will show an alarm once 1900 hours of lamp life are exceeded and, in case tha lamp is not
replaced within 2100 hours, the projector will not turn on.
Every time the lamp is replaced, please reset the lam-
plife counter
, as described in paragraph 12.3, in order to determine when to perform the next replacement.
12.3 Reset of the lamp life
To reset the lamp life, press “UP” and “DOWN” until you see “LMP”. Press “ENTER” to confirm. Press “UP” and
“DOWN” until you see “RLL” (Reset Lamp Life). Press “ENTER”. You will be asked to confirm the operation. If you
confirm (Yes) lamp life will be reset to zero.
13.1 Default parameters
With this operation ALL the parameters can be set to the default values.
In order to activate the function, press the "MENU" button until you see "ADR". Press the "UP" or "DOWN" until "UTI".
Press the "UP" or "DOWN" until "DEF". Press "ENTER" to confirm.
Select “RES” or “CAN” to reset value or cancel operation.
Following parameters will be set to default values: DMX address, automatic mode, colour mode.
13.2 Reset
This function allows to manually perform the reset of the projector’s motors.
The motors of CYM filters, zoom, frost filter and black-out will be moved.
In order to activate the function, press the "MENU" button until you see "ADR". Press the "UP" or "DOWN" until "UTI".
Press the "UP" or "DOWN" until "RES". Press "ENTER" to confirm.
Select "RES" or "CAN" to reset the motors or cancel the operation.
13.3 Blackout calibration
This function allows to calibrate the blackout reset point.
Press the “MENU” button until you see “ADR” to activate this function. Press the "UP" or "DOWN" until "UTI". Press the
"UP" or "DOWN" until "CBO". Press "ENTER" to confirm, and then, by pressing the "UP" or "DOWN" to select the de-
sired value (0-255). Press "ENTER" to confirm.
13.4 Fixture test
Using this function, you can perform a test of the functions of the projector.
To activate the function, press the "MENU" button until you see "ADR". Press the "UP" or "DOWN" until "UTI". Press the
"UP" or "DOWN" until "TES". Press "ENTER" to confirm.
The projector will start testing all the functions and the display will show which function is being tested.
Press the "MENU" button to stop the test and exit function.
12.0 Lamp management
13.0 Utility function
English
43