138
Program description: Telemetry menu
Telemetry
The menus grouped together under the overall head-
ing “
Telemetry
” are called up from the basic display of
the
mx-16
HoTT transmitter by holding the central
ESC
button of the left-hand touch-key pressed in for
about one seconds. An alternative method of calling up
this menu, which also applies to the transmitter’s other
menus, is to briefly press the central
SET
button of the
right-hand touch-key in the multi-function list:
mod. mem.
servo set.
D/R expo
wing mixer
base sett.
contr set.
phase trim
free mixer
servo disp
basic sett
fail-safe
telemetry
Basic menu operation
In general terms the “
Telemetry
” menu is operated just
like the other menus of the
mx-16
HoTT transmitter.
The few differences are described below:
You can switch between the individual pages of the
Telemetry menu using the arrow buttons
of the
left or right-hand touch-key: the corresponding direction
indicators can be found at top right of every screen page
in the form of pointed brackets (<>); see the following
illustrations. If only one angle bracket is visible, then you
are currently at the first or last page. In this case it is
only possible to switch pages in the direction indicated
by the angle bracket.
Menu lines in which parameters can be altered are
marked with an angle bracket prefix (>). Pressing the
arrow buttons
of the left or right-hand touch-key
causes the “>” pointer to jump forward or back by one
line. Lines to which you cannot jump contain no user-
variable values.
If you wish to change a parameter, touch the central
SET
button of the right-hand touch-key to highlight the
parameter (black background)). Change the value within
the possible range using the arrow buttons of the
right-
hand
touch-key, and then press the
SET
button again
briefly to accept the value.
At this point you can use the arrow buttons
of the
left or right touch-key to select the desired sub-menu.
However, if the message …
CAN‘T
RECEIVE
DATA
OK
… appears instead of the desired sub-menu when you
touch the central
SET
button of the right-hand touch-key,
then the transmitter has no connection to a receiver. In
this case, switch your receiving system on, or re-bind
the receiver you wish to address, as described on page
72 and 80; alternatively activate the receiver as de-
scribed on the previous page under “Important notes”.
TELEMETRY
SETTING & DATA VIEW
SENSOR SELECT
RF STATUS VIEW
VOICE TRIGGER
On the first screen page of the sub-menu “Setting &
Data View”, headed …
RX DATAVIEW
… you cannot enter any settings. This page is for infor-
mation purposes only:
RX DATAVIEW
S–STR100% R–TEM.+28°C
L PACK TIME 00010msec
R-VOLT :05.0V
L.R-VOLT:04.5V
S–QUA100%S–dBM–030dBM
SENSOR1 :00.0V 00°C
SENSOR2 :00.0V 00°C
Value
Explanation
S-QUA
Signal quality in %
S-dBm
Receive performance in dBm
S-STR
Signal strength in %
R-TEM.
Receiver temperature in °C
L PACK TIME Indicates the time in ms for which
the longest data packet was lost in
transmission between transmitter and
receiver
R-VOLT
Current receiver operating voltage, in
Volt
SETTING & DATA VIEW
Содержание mx-12 Hott
Страница 1: ...Programming Manual 33116 mx 16 HoTT 3 en mx 16...
Страница 35: ...35 For your notes...
Страница 49: ...49 For your notes...
Страница 55: ...55 For your notes...
Страница 59: ...59 For your notes...
Страница 63: ...63 For your notes...
Страница 69: ...69 For your notes...
Страница 91: ...91 For your notes...
Страница 101: ...101 For your notes...
Страница 123: ...123 For your notes...
Страница 181: ...181 For your notes...
Страница 193: ...193 For your notes...