Upgrade LSI RAID controller driver
Do not do this task if:
•
A K2 Solo Media Server
•
A K2 Summit Production Client with direct-connect storage
•
A K2 Summit Production Client installed new with K2 software version 7.1.x or higher, in which
case the driver is pre-installed at version 3.10.0.32.
•
A K2 Summit Production Client with the driver already upgraded to version 3.10.0.32.
Do this task if:
•
A K2 Summit Production Client with internal storage and a driver at a version lower than
3.10.0.32.
1. If you are not sure of the driver version currently installed, do the following:
a) open Windows
Device Manager | SCSI and RAID controllers | LSI MegaRAID SAS PCI Express
ROMB | Properties | Driver
.
b) Check file properties. The following properties indicate that version 3.10.0.32 is already
installed:
Date
Version
7/22/2009
3.10.0.32
c) If the upgrade is necessary, continue with this procedure.
2. Open Windows
Device Manager | SCSI and RAID controllers
.
3. Right-click
LSI MegaRAID SAS PCI Express ROMB
and select
Update driver
.
An install wizard opens.
4. Select
No, not this time
and click
Next
.
5. Select
Install from a list or specific location [Advanced]
and click
Next
.
6. Select
Don't search. I will choose the driver to install
and click
Next
.
7. Click
Have disk
.
8. Click
Browse
, navigate to the
LSI_1078_winxp
directory, select
oemsetup.inf
, and click
OK.
9. Click
Next
.
10. When prompted regarding Windows Logo Compatibility, select
Continue Anyway
and click
Finish
.
11. Restart as prompted.
Upgrade MegaRAID Storage Manager
Do not do this task if:
•
A K2 Solo Media Server
•
A K2 Summit Production Client with direct-connect storage
•
A K2 Summit Production Client installed new with K2 software version 7.1.x or higher, in which
case MegaRAID Storage Manager is pre-installed at version 2.91-05.
23 November 2010
K2 Version 7.3.8 Release Notes & Upgrade Instructions
73
Upgrading K2 systems