Advanced Functions and Settings: AXIS ALIGNMENT - Axis Alignment Parameter Setting
89
• Press the POSITION key to move the loupe to Axis Point 3.
• Press the ENTER key to store the setting. The following menu appears.
• Press the POSITION key to move the loupe to Axis Point 4.
• Press the ENTER key to store the setting. The following menu appears.
• Use the POSITION key to change the distance value to that of the printed
image, i.e. the distance between point 1 and point 2. The measured value is
shown on the 3rd row. Set the actual distance on the 4th row.
If no changes need to be made, press the ENTER key.
• Press the RIGHT or LEFT ARROW key to move the cursor.
• Press the UP or DOWN arrow key to increase or decrease the number for
the distance value.
• Press the ENTER key to store the setting.
The following menu appears:
• Use the POSITION key to change the distance value to that of the printed
image, i.e. the distance between point 1 and point 3. If no changes need to
be made, press the ENTER key.
• Press the RIGHT or LEFT ARROW key to move the cursor.
• Press the UP or DOWN arrow key to increase or decrease the number for
the distance value.
• Press the ENTER key to store the setting.
• The READY menu appears, and the plotter is ready to start the cutting
operation.
AXIS POINT 4
.
X=
...
0 mm
Y=
...
0 mm
DISTANCE
POINT 1-2
00099.8 mm
.
OK?
..........
00100.0 mm
.
DISTANCE
POINT 1-3
00101.1 mm
.
OK?
..........
00100.0 mm
.
Содержание FC5100A-100
Страница 1: ...A 75 100 130 150 user manual MANUAL NO FC5100 UM 154...
Страница 3: ......
Страница 10: ...FC5100A Loupe PHP 61 Loupe 197 Attaching the Loupe 197 Using the Loupe 198 Chapter 11 Appendix 200...
Страница 11: ......
Страница 27: ...Out of the Box Connecting the Plotter 27...
Страница 33: ...Cutters and Holders Blade Length 33...
Страница 133: ...Advanced Functions and Settings RS 232C Serial Interface 133...
Страница 149: ...Background Settings Background Settings for HP GL 149...
Страница 199: ...Options FC5100A Loupe PHP 61 Loupe 199...