Advanced Functions and Settings: DISTANCE ADJUST - Adjusting the Length of Line Segments
129
• Press the UP or DOWN ARROW key to sequence through the availabe
choices. The INITAL DOWN FORCE can be set from 0 to 40.
• Press the ENTER key to register your settings.
• Press the MENU key to cancel the menu mode.
NOTE:
Your INITIAL DOWN FORCE setting specifics additional pressure. The plotter
applies higher force on the blade for a short time after it changes the direction
of the blade in TANGENTIAL EMULATION MODE and then the plotter returns
to the original cutting force on the blade for cutting the material The higher
force is the total of the original cutting force setting plus the INITIAL DOWN
FORCE setting.
DISTANCE ADJUST - Adjusting the Length of Line Seg-
ments
The actual length of cut line segments may vary according to the thickness of
the media being used. In this case, use the DISTANCE ADJUST function to cor-
rect the distance.
Each of the DISTANCE ADJUST settings represents a percentage. For example,
if the cutting length is 2000mm and the DISTANCE ADJUST setting is 0.5% then
the cutting length would be 2001mm.
• Press the MENU key to select MENU mode.
• Press the NEXT key three times.
• Press the F4 key to select OPTION 2.
• Press the F3 key to select DISTANCE ADJUST.
• Press the RIGHT or LEFT ARROW key to move the cursor to the number of
the condition group you wish to use under DISTANCE ADJUST. Press the
INITIAL DOWN FORCE
FORCE = 0
.
BACKGROUND SETTINGS>
.
OPTION 1>
.
OPTION 2>
.
.
INITIAL DOWN FORCE>
.
DISTANCE ADJUST>
.
TEST>
.
Содержание FC5100A-100
Страница 1: ...A 75 100 130 150 user manual MANUAL NO FC5100 UM 154...
Страница 3: ......
Страница 10: ...FC5100A Loupe PHP 61 Loupe 197 Attaching the Loupe 197 Using the Loupe 198 Chapter 11 Appendix 200...
Страница 11: ......
Страница 27: ...Out of the Box Connecting the Plotter 27...
Страница 33: ...Cutters and Holders Blade Length 33...
Страница 133: ...Advanced Functions and Settings RS 232C Serial Interface 133...
Страница 149: ...Background Settings Background Settings for HP GL 149...
Страница 199: ...Options FC5100A Loupe PHP 61 Loupe 199...