Advanced Functions and Settings: AUTO REG. MARK - Auto Registration Mark Sensor
110
• Press the F3 or F4 key to select the axis for setting distance.
Press the F2 key
to change polarity for distance setting. Press the LEFT or RIGHT
ARROW key to move the blinking cursor to select a digit, then press the
UP or DOWN ARROW key to change the number.
In the X-Axis, enter the distance between registration mark 1 and the axis origin
point on the X-axis. In the Y-Axis, enter the distance between registration mark
1 and the axis origin point on the Y-axis. The distance can be set from -
200mm to 200mm.
Press the F2 key to toggle polarity, the “–“ mark appears on the distance setting
when you’ve selected negative.
• Press the ENTER key to register your setting.
The following menu appears.
If you wish to set another parameter, press the key corresponding to
that setting.
AXIS ORIGIN OFFSET
+/- >
.
X =
...
000.0 mm
**
Y =
...
000.0 mm
**
Y
Mark
3
Mark
2
Mark
1
X
Axis
Origin
Point
Plotter's
Origin
Point
X
Pattern
1
Mark
1
Mark
3
Mark
2
Media
feed
direction
Axis
Origin
Point
Plotter's
Origin
Point
Y
Pattern
2
MARK SIZE>
*
SENSOR OFFSET ADJ>
*
AXIS ORIGIN OFFSET>
*
PAPER-WEIGHT>
*
Содержание FC5100A-100
Страница 1: ...A 75 100 130 150 user manual MANUAL NO FC5100 UM 154...
Страница 3: ......
Страница 10: ...FC5100A Loupe PHP 61 Loupe 197 Attaching the Loupe 197 Using the Loupe 198 Chapter 11 Appendix 200...
Страница 11: ......
Страница 27: ...Out of the Box Connecting the Plotter 27...
Страница 33: ...Cutters and Holders Blade Length 33...
Страница 133: ...Advanced Functions and Settings RS 232C Serial Interface 133...
Страница 149: ...Background Settings Background Settings for HP GL 149...
Страница 199: ...Options FC5100A Loupe PHP 61 Loupe 199...