12-6
Error Messages in GP-GL Command Mode
Error
Displayed
LCD Display
Cause
Solution
E02001
The plotter received an unrecognizable
command.
Press the [ENTER] key.
Nose came n when the computer was
turned on.
Configure to drive the plotter from the menu
of the software.
The software configuration regarding the
output devce has been changed.
Reset the nterface settngs of the software.
The plotter's nterface condtons have
changed.
Reset the nterface settngs of the plotter.
E02004
A command was receved contanng
numerc parameters that exceed that
command's permssble range.
Configure to drive the plotter from the menu
of the software.
The software configuration regarding the
output devce has been changed.
Reset the nterface settngs of the software.
The plotter's nterface condtons have
changed.
Reset the nterface settngs of the plotter.
E02005
An error occurred n the recept of data
wthn the nterface.
Configure to drive the plotter from the menu
of the software.
The software configuration regarding the
output devce has been changed.
Reset the nterface settngs of the software.
The plotter's nterface condtons have
changed.
Reset the nterface settngs of the plotter.
E02006
The data out of cuttng range has been
receved.
Check the data.
Check the size of media and the cutting
range.
Check the magnification setting.
Check the step size settings.
Содержание CE6000-120AP
Страница 1: ...USER S MANUAL MANUAL NO CE60AP UM 153 CUTTING PLOTTER CE6000 120AP...
Страница 200: ...12 12 Caution Message Symptom LCD Display Description W06002 When panel cutting is on copy cannot be changed...
Страница 214: ...A 4 CE6000 120AP 1575 1250 1200 Unit mm Dimensional accuracy 5mm A 3 External Dimensions...
Страница 218: ...A 8 Default screen Continued MENU screen 4 PAUSE MENU MEDIA SETTING 1 3 MEDIA SETTING 2 3 MEDIA SETTING 3 3 Continued...
Страница 219: ...A 9 INTERFACE 1 3 INTERFACE 2 3 MENU screen PAUSE MENU Continued Default screen Continued INTERFACE 3 3...
Страница 227: ......