Installation
20
309028ZAT
Installation
The installation procedures in this section are intended
to serve as a guide for installing the Uni-Drum Supply
System. If you need more information, contact your
Graco distributor.
NOTE:
When raising and lowering the Ram, be sure
that the unit is unobstructed overhead to avoid
interference with other objects.
Preparing the Site
Ensure that you have an adequate compressed air supply.
Refer to the applicable instruction manual listed in
on page 3 to find the air consumption of your
Pump. Approximately 450 cfm at 80 psi is required to
operate the Pumps at the maximum rate.
Keep the site clear of any obstacles or debris that could
interfere with the installer’s and operator’s movement.
Selecting a Location for the
Uni-Drum
Refer to
on page 94 for ram
mounting and clearance dimensions.
When selecting a location for the Uni-Drum, keep the
following in mind:
1. There should be sufficient space for installing,
servicing, and using the equipment.
• Select an accessible location for the system.
There must be sufficient space around the
system for maintenance.
• Select a convenient location for the equipment.
Check that there is sufficient overhead clearance
for the Pump and ram when the ram is in the fully
raised position. Make sure the Air Regulators
(AC, AE) for the Pumps (C) and Follower Plate
(D) are fully accessible.
• Make sure the air source for the PLC control
panel and shutoff valves are fully accessible.
• Make sure there is easy and safe access to an
appropriate pneumatic source. Graco
recommends a minimum of 3 feet (0.91 m) of
open space in front of the Pneumatic Logic Panel
(G).
2. Make sure that you will be able to level the base of
the ram using metal shims.
Preparing to Install the
Uni-Drum
Before installing the system:
•
See component manuals for specific data on
component requirements. Data presented here
pertains to the system only.
•
Have all system and subassembly documentation
available during installation.
•
Be sure that all non-Graco supplied hoses are
adequately sized and pressure-rated to meet the
system requirements.
The Uni-Drum Supply System is supplied with every
major component attached and weighs approximately
3950 lb (1792 kg). The Uni-Drum Supply System
should never be moved or lifted by one person. To
avoid serious injury or equipment damage, engage an
adequate number of personnel and use a forklift,
hand truck, and support devices, such as a hoist
when moving and installing the Uni-Drum.
NOTICE
Exercise care when the system is being moved to its
installed location. Jarring, dropping, or tilting the frame
while it is being lifted or moved can result in damage to
the system.
Содержание 309028ZAT
Страница 14: ...Component Identification 14 309028ZAT FIG 5 Pneumatic Logic Panel Interior AJ AK AL ...
Страница 41: ...Junction Box Panel Service 309028ZAT 41 FIG 20 T10196 Pressure Switch Solenoid Valve ...
Страница 75: ...Parts 309028ZAT 75 Follower Plate Assembly 241891 and 243510 FIG 32 ...
Страница 77: ...Parts 309028ZAT 77 PLC Pneumatic Logic Panel FIG 33 915 909 905 915 910 917 906 ...
Страница 78: ...Parts 78 309028ZAT FIG 34 945a 955 939a 912b 912a 914a 954a 909a 953a 901b 902b ...
Страница 80: ...Parts 80 309028ZAT PLC Interface Accessory Kit 241838 and 24V775 FIG 35 ...
Страница 82: ...Parts 82 309028ZAT Junction Box Panel 195320 and 119773 FIG 36 ...
Страница 84: ...Parts 84 309028ZAT Follower Plate 233041 FIG 37 413c 413b 413a DETAIL A DETAIL B SEE DETAIL B SEE DETAIL A ...
Страница 88: ...Parts 88 309028ZAT Elevator Assembly 241902 FIG 39 Ref Ref Ref ...
Страница 93: ...Pneumatic Diagram 309028ZAT 93 ...