Operation
28
309028ZAT
Flushing the System Before
Initial Use
Flushing the system before its initial use can prevent
material contamination, which may cause the material to
fail or perform poorly.
The equipment was tested with lightweight oil, which is
left in the fluid passages to protect parts. To avoid
contaminating your fluid with oil, flush the equipment
with a compatible solvent before using the equipment.
To flush the system, perform the following procedure:
1. Select the material for the initial material load.
2. Verify whether the factory-test oil and the initial
material load are compatible:
a. If the two substances are compatible, omit the
remaining steps in this procedure and perform
the
Initial System Startup Procedure
on page
b. If the two substances are incompatible, perform
the remaining steps in this procedure to flush
the system.
NOTE:
Use fluids and solvents that are chemically
compatible with the equipment wetted parts. See the
sections of all the equipment
manuals. Always read the material manufacturer’s
literature before using fluid or solvent in this Pump.
3. Select a drum containing a compatible material that
can dissolve, clean, and eliminate the factory test oil
from the system. If necessary, check with the
material supplier for a recommended flush material.
4. Before flushing, be sure the entire system and
flushing drums are properly grounded. Refer to
on page 24.
5. Perform steps 9 through 15 of the
on page 29 to load the drum
containing the solvent.
6. Run the flush material through the system for
approximately 1 to 2 minutes.
7. Remove the drum containing the flush material.
Adjusting the Drum Lid Holder
Before Initial Use
1. Adjust the lower Drum Lid Holder (J) channel as low
as it will go on the side of the ram post. The channel
should be 1 in. (25 mm) higher from the floor in the
front compared to the back.
2. Loosen the upper Drum Lid Holder (J) channel.
Place the lid in the center of the lower channel.
Lower the upper channel until it contacts the lid. Tilt
the rear of the upper channel down 1/2 to 1 in. (13 to
25 mm) and tighten all bolts.
3. The lid should roll in and out from the front and not
roll out the rear.
To avoid fire and explosion, always ground equipment
and waste container. To avoid static sparking and
injury from splashing, always flush at the lowest
possible pressure.
NOTICE
There must be a minimum of 10 feet (3 m) of fluid
supply hose on the outlet to prevent damage to the
unit.
F
IG
. 12
J
Содержание 309028ZAT
Страница 14: ...Component Identification 14 309028ZAT FIG 5 Pneumatic Logic Panel Interior AJ AK AL ...
Страница 41: ...Junction Box Panel Service 309028ZAT 41 FIG 20 T10196 Pressure Switch Solenoid Valve ...
Страница 75: ...Parts 309028ZAT 75 Follower Plate Assembly 241891 and 243510 FIG 32 ...
Страница 77: ...Parts 309028ZAT 77 PLC Pneumatic Logic Panel FIG 33 915 909 905 915 910 917 906 ...
Страница 78: ...Parts 78 309028ZAT FIG 34 945a 955 939a 912b 912a 914a 954a 909a 953a 901b 902b ...
Страница 80: ...Parts 80 309028ZAT PLC Interface Accessory Kit 241838 and 24V775 FIG 35 ...
Страница 82: ...Parts 82 309028ZAT Junction Box Panel 195320 and 119773 FIG 36 ...
Страница 84: ...Parts 84 309028ZAT Follower Plate 233041 FIG 37 413c 413b 413a DETAIL A DETAIL B SEE DETAIL B SEE DETAIL A ...
Страница 88: ...Parts 88 309028ZAT Elevator Assembly 241902 FIG 39 Ref Ref Ref ...
Страница 93: ...Pneumatic Diagram 309028ZAT 93 ...