Operation
309028ZAT
31
b. Verify that the Follower Plate (D) lowers to the limit
set point: a level between 1 -4 in. (25.4
-101.6
mm) from the bottom of the drum.
c. Adjust the low limit switch to activate at the level
defined in step 37.b. See F
. 13.
Changing Empty Drums
NOTE:
After the automatic Pump crossover has taken
place, immediately replace the empty drum with a new,
full drum. If both Uni-Drums become empty at the same
time:
•
Material will stop being delivered to the dispenser.
•
Air may enter the supply hose or pipe header.
•
Pump runaway could occur, resulting in damage to
the Pumps.
Drum Changing Procedure
To remove an empty drum and load a new, full drum:
1. If used, verify that the two front and rear Drum
Clamps (K) are engaged on the Uni-Drum ram
base.
2. Check that the Pump air is turned off. On the
Junction Box Panel (H), the PUMP ACTIVE and
PUMP READY lights are not lit.
3. Check that the RAM UP Air Regulator (AJ) is set to
50 psi. It is not recommended to exceed 80 psi.
4. Close the two ball valves at the outlet manifold at
the rear of the Uni-Drums.
5. To raise the Follower Plate (D):
a. Set the RAM POSITION Switch (AG) to RAISE,
then wait 5 seconds.
NOTE:
If RAM UP Pushbutton (AF) is pushed within 5
seconds, the vent valves may open before the pressure
under the Follower Plate (D) is relieved causing the
material to bleed past the vents.
b. Push and hold the RAM UP Pushbutton (AF) as
the Follower Plate (D) slowly rises.
6. With the ram raised and the RAM POSITION Switch
(AG) set to RAISE, pull the Drum Clamps (K) (if
used) back and remove the empty drum, using a
suitable lifting device.
7. Being careful not to damage the Follower Plate (D)
wipers, wipe or scrape any material buildup from the
Follower Plate (D) and wipers, and properly dispose
of the waste material.
F
IG
. 13
TI0200
1 to 4 in.
(25.4 to
101.6 mm)
Limit Switches
Pin 1
Pin 3
Pin 5
Pin 2
Pin 4
Use a long-handled flat-bladed ice scraper if it is
necessary to scrape the bottom of the Follower
Plate (D). To avoid serious injury, do not put your
hands between the plate and the drum.
Содержание 309028ZAT
Страница 14: ...Component Identification 14 309028ZAT FIG 5 Pneumatic Logic Panel Interior AJ AK AL ...
Страница 41: ...Junction Box Panel Service 309028ZAT 41 FIG 20 T10196 Pressure Switch Solenoid Valve ...
Страница 75: ...Parts 309028ZAT 75 Follower Plate Assembly 241891 and 243510 FIG 32 ...
Страница 77: ...Parts 309028ZAT 77 PLC Pneumatic Logic Panel FIG 33 915 909 905 915 910 917 906 ...
Страница 78: ...Parts 78 309028ZAT FIG 34 945a 955 939a 912b 912a 914a 954a 909a 953a 901b 902b ...
Страница 80: ...Parts 80 309028ZAT PLC Interface Accessory Kit 241838 and 24V775 FIG 35 ...
Страница 82: ...Parts 82 309028ZAT Junction Box Panel 195320 and 119773 FIG 36 ...
Страница 84: ...Parts 84 309028ZAT Follower Plate 233041 FIG 37 413c 413b 413a DETAIL A DETAIL B SEE DETAIL B SEE DETAIL A ...
Страница 88: ...Parts 88 309028ZAT Elevator Assembly 241902 FIG 39 Ref Ref Ref ...
Страница 93: ...Pneumatic Diagram 309028ZAT 93 ...