Casing and seal chamber cover areas to inspect
The arrows point to the areas to inspect for wear on the casing:
164
100
125
230
184
100
Casing
184
Seal chamber cover
164
Casing wear ring
230
Seal chamber cover wear ring
Figure 51: Areas to inspect for wear on casing and seal chamber cover
Impeller replacement
This table shows the criteria for replacing the impeller:
Impeller parts
When to replace
Impeller vanes
•
When grooved deeper than 1.6 mm | 1/16 in., or
•
When worn evenly more than 0.8 mm | 1/32 in.
Pumpout vanes
When worn or bent more than 0.8 mm | 1/32 in.
Vane edges
When you see cracks, pitting, or corrosion damage
Wear ring surfaces Wear ring clearances that exceed the values in the minimum running clearances table
Impeller checks
NOTICE:
When clearances between the rings become excessive (increase by 50%), hydraulic perform-
ance decreases substantially.
NOTICE:
Protect machined surfaces while cleaning the parts. Failure to do so may result in equipment
damage.
6.5 Preassembly inspections
78