12. If your power end has the optional water cooling package, install the finned-tube cooling assembly
into the bearing frame.
6.6.3 Install the seal-chamber cover
WARNING:
Lifting and handling heavy equipment poses a crush hazard. Use caution during lifting and
handling and wear appropriate Personal Protective Equipment (PPE, such as steel-toed shoes,
gloves, etc.) at all times. Seek assistance if necessary.
1.
Install the eyebolt in the tapped hole provided in the seal-chamber cover (184).
184
122
228
370H
Figure 70: Seal chamber cover
2.
Set up a sling from the eyebolt to the overhead lifting device.
3.
Lift the seal-chamber cover and position it so that it aligns with the shaft (122).
4.
Install the seal-chamber cover on the bearing-frame assembly:
a) Guide the cover carefully over the shaft and into the bearing-frame lock.
b) Install the seal-chamber cover and bearing-frame bolts (370H).
c)
Tighten the bolts evenly using an alternating pattern.
Torque the bolts to values shown in the Maximum torque values for 3700i fasteners table.
5.
Check the seal-chamber cover face runout:
a) Mount the dial indicator on the shaft.
b) Rotate the shaft so that the indicator rides along the seal-chamber cover face for 360°.
If the total indicator reading is greater than 0.13 mm | 0.005 in., determine the cause and correct it.
6.6 Reassembly
Model 3700i API610 / Type OH2 Installation, Operation, and Maintenance Manual
101