Do not open the product while it is energized or in an explosive gas atmosphere.
•
Make sure that thermal contacts are connected to a protection circuit according to the approval
classification of the product, and that they are in use.
•
Intrinsically safe circuits are normally required for the automatic level-control system by the level
regulator if mounted in zone 0.
•
The yield stress of fasteners must be in accordance with the approval drawing and the product
specification.
•
Do not modify the equipment without approval from an authorized ITT representative.
•
Only use parts that are provided by an authorized ITT representative.
Description of ATEX
The ATEX directives are a specification enforced in Europe for electrical and non-electrical equipment
installed in Europe. ATEX deals with the control of potentially explosive atmospheres and the standards
of equipment and protective systems used within these atmospheres. The relevance of the ATEX re-
quirements is not limited to Europe. You can apply these guidelines to equipment installed in any poten-
tially explosive atmosphere.
Guidelines for compliance
Compliance is fulfilled only when you operate the unit within its intended use. Do not change the condi-
tions of the service without the approval of an ITT representative. When you install or maintain explosion
proof products, always comply with the directive and applicable standards (for example, IEC/EN
60079-14).
1.
Monitoring the liquid end temperature.
2.
Maintaining proper bearing lubrication.
3.
Ensuring that the pump is operated in the intended hydraulic range.
The ATEX conformance is only applicable when the pump unit is operated within its intended use. Oper-
ating, installing or maintaining the pump unit in any way that is not covered in the Instruction, Operation,
and Maintenance manual (IOM) can cause serious personal injury or damage to the equipment. This in-
cludes any modification to the equipment or use of parts not provided by ITT Goulds Pumps. If there is
any question regarding the intended use of the equipment, please contact an ITT Goulds representative
before proceeding.
https://www.gouldspumps.com/en-US/Tools-and-Resources/Literature/
or from your local ITT Goulds Pumps Sales representative.
All pumping unit (pump, seal, coupling, motor and pump accessories) certified for use in an ATEX classi-
fied environment, are identified by an ATEX tag secured to the pump or the on which it is mounted. A
typical tag would look like this:
Figure 1: Typical ATEX pump nameplate
The CE and the Ex designate the ATEX compliance. The code below reads as follows:
1.4 ATEX Considerations and Intended Use
10