Check
Procedure
Shaft impeller fit
1.
Mount the dial indicator on the bearing frame.
2.
Rotate the shaft through a maximum arc from one side of the keyway to
the other. If the total indicator reading is greater than 0.030mm | 0.001in.,
determine the cause and correct it.
122
228
Shaft seal fit
1.
Mount the dial indicator.
2.
Rotate the shaft so that the indicator rides along the shaft surface for
360°. If the total indicator reading is greater than 0.030mm | 0.001in.,
then determine the cause and correct it.
122
228
Bearing-frame face
1.
Mount the dial indicator on the shaft.
6.6 Reassembly
Model 3700i API610 / Type OH2 Installation, Operation, and Maintenance Manual