Recognize the site emergency exits, eye wash stations, emergency showers and toilets.
•
Allow all system and pump components to cool before you handle them.
•
Make sure that you have a clear path of retreat.
•
Make sure that the product cannot roll or fall over and injure people or damage property.
•
Make sure that the lifting equipment is in good condition.
•
Use a lifting harness, a safety line, and a breathing device as required.
•
Make sure that the product is thoroughly clean.
•
Make sure that there are no poisonous gases within the work area.
•
Make sure that you have quick access to a first-aid kit.
•
Disconnect and lock out power before servicing.
•
Check the explosion risk before you weld or use electric hand tools.
1.2.3.2 Wash the skin and eyes
1.
Follow these procedures for chemicals or hazardous fluids that have come into contact with your
eyes or your skin:
Condition
Action
Chemicals or hazardous fluids
in eyes
1.
Hold your eyelids apart forcibly with your fingers.
2.
Rinse the eyes with eyewash or running water for at least 15 minutes.
3.
Seek medical attention.
Chemicals or hazardous fluids
on skin
1.
Remove contaminated clothing.
2.
Wash the skin with soap and water for at least 1 minute.
3.
Seek medical attention, if necessary.
1.2.4 Product approval standards
Regular standards
WARNING:
Use of equipment unsuitable for the environment can pose risks of ignition and/or explosion.
Ensure the pump driver and all other auxiliary components meet the required area classifica-
tion at the site. If they are not compatible, do not operate the equipment and contact an ITT
representative before proceeding.
All standard products are approved according to CSA standards in Canada and UL standards in USA.
The drive unit degree of protection follows IP68 See the nameplate for maximum submersion, according
to standard IEC 60529.
All electrical ratings and performance of the motors comply with IEC 600341.
1.3 Product warranty
Coverage
ITT undertakes to remedy faults in products from ITT under these conditions:
•
The faults are due to defects in design, materials, or workmanship.
•
The faults are reported to an ITT representative within the warranty period.
•
The product is used only under the conditions described in this manual.
•
The monitoring equipment incorporated in the product is correctly connected and in use.
1.3 Product warranty
8
Model 3700i API610 / Type OH2 Installation, Operation, and Maintenance Manual