Device Description HG G-19603ZA | English, Revision 03 | Date: 31.03.2021
44
Chapter 11 – Technical Data
11
Technical Data
Table 39
Technical Data
Technical Data
Nominal reading dis
-
tance
60 mm when using the Götting magnetic tape HW
MAT00003, see Table 2 on page 11. For different mag
-
netic tape a different reading height might be needed.
Dimensions
156.5 mm x 31 mm x 53 mm (W x H x D)
Casing
Polycarbonate
Weight
200 g
Protection class
IP 54
Relative humidity
95 % at 25° C (without condensation)
Temperature ranges
Operation: -20° to +50° C | Storage: -20° to +70° C
Supply voltage
+ 24 VDC
Current consumption
< 30 mA
Connectors
–
PWR / USB: M12 circular connector, 5 pin, A coded,
male
–
CAN1: M12 circular connector, 5 pin, A coded,
female
–
CAN2: M12 circular connector, 5 pin, A coded, male
Display elements
5 LEDs
Output/Resolution
–
Position of the track (Output_X): -10.00 to +10.00 in
steps of 0.01
–
Field strength (Output_Z): 0.00 to +10.00 in steps if
0.01
Measuring accuracy
Repeatability: 0.05 of the output (without external inter
-
ferences)
Working range
–
Height above magnetic tape: 40 to 70 mm
–
Detection range track: ±80 mm
–
Effective detection range track: ±55 mm