Device Description HG G-19603ZA | English, Revision 03 | Date: 31.03.2021
25
Software – Chapter 6
The driver may be downloaded from the following address:
http://www.st.com/en/development-tools/stsw-stm32102.html
6.3 Terminal Program
Every terminal program compatible with the transmission parameters shown above
can be used, examples are HyperTerminal® or Tera Term®. HyperTerminal has been
included in earlier versions of Microsoft® Windows®. Additionally it can be down
-
loaded from the following address:
https://www.hilgraeve.com/hyperterminal/
Start the terminal program on the PC and connect the COM port with the pins TxD,
RxD und GND of the magnet sensor. When the connection is established success
-
fully the main menu as shown in section 6.4 appears. Sometimes it is necessary to
refresh the menu with the key
.
6.4 Service Program
6.4.1 Main Menu
Figure 16
Main menu
The service program shows the current system status. In its first line the serial num
-
ber and the software version are output. Below a visual representation of the sensor
casing follows that shows the position of detected magnetic tapes.
HG 19603 Serialnumber: 123456 Firmwareversion: V1.01
system monitor
__ __
| | | |
---------------------------------
| HG 19603 O O O O O |
| |
---------------------------------
X
next turn: STRAIGHT
position track: 7.50
(L) left
error: 0x00 (R) right
(S) straight
(D) CAN input
(1) CSV Output
(2) settings
(3) raw data
CAN Status: Rx: 172 Tx: 133 OutX: 7.50 OutZ: 1.26 Out: 0x01 In: 0x00