26
MDE-LEDI-NETWORK-TDS-4099V3.0
►
DCF or GPS synchronisation input
►
The third line shows the current alarms. If several alarms are active, each will be
displayed successively for a few seconds. The following section describes the
meaning of the alarms.
4.4. ALARM DISPLAY
When a short description alarm occurs, it appears on the third line of the display and the
LCD/OLED backlight flashes.
The following is a list of possible alarms and their meanings:
►
FREE RUNNING
:
the server has been forced into autonomous operating mode. No time
input is used for synchronisation. Useful for test purposes.
►
NO TIME CODE!
:
the time sources are not available (GPS signal not received, no NTP
server available…)
►
AUTONOMY CRITICAL!
:
there is no available source of synchronisation and the server
is about to switch the outputs off (3 remaining minutes of autonomy).
►
NEVER SYNC!
:
the server has been running for at least 15 minutes and there is still no
valid synchronisation source available.
►
ETHERNET LINK ERROR
:
there is a problem with the network cable connection.
►
OUTPUT ALARM!
: one or more output cards are not detected by the main control
board. You can check the status of the output cards in the web page in the “Output”
tab. This status may occur temporarily during initialisation and in normal operation.
If the fault persists and the corresponding outputs no longer emit time codes, please
contact Gorgy Timing Customer Service.
►
SERVER LOCKED
: the time outputs have been disabled by a user.
►
SYNC ALARM!
: there is no time source available and the server has no more
autonomy.
►
SECURITY LOCKDOWN!
: the configuration interfaces are locked for 5 minutes
following 3 authentication failures.