background image

www.goodmanmfg.com IO-412A

IO-412A www.goodmanmfg.com 

7

D

iamètre

 

extérieUr

 

(

poUceS

 

et

 

mm

)

a (

poUceS

 

et

 

mm

)

m

ax

m

in

.

1/4 po. (6,35)

3/64 po. (1,3)

1/32 po. (0,7)

3/8 po. ( 9,52)

1/16 po. (1,6)

3/64 po. (1,0)

1/2 po. (12,7)

1/16 po. (1,8)

3/64 po. (1,0)

5/8 po. (16,0)

3/32 po. (2,2)

3/32 po. (2,2)

 

Figure 19

 

5.  Serrer les connexions : 
  Alignez le centre des tuyaux et serrez manuellement l'écrou 

d'évasement. À l'aide d'une clé et d'une clé dynamométrique 
(Figures 20 et 21) continuez à serrer l'écrou d'évasement jusqu'à 
ce que l'écrou soit bien serré sur le tuyau.  

D

iamètre

  

extérieUr

 (

mm

)

c

oUple

 

De

 

Serrage

c

oUple

 

De

 

Serrage

 

SUpplémentaire

1/4 po. (Ф6,35)

11 lb.-pi. 

1 500 (N-cm)

11,8 lb.-pi. 

1 600 (N-cm)

3/8 po. (Ф9,52)

18,5 lb.-pi. 

2 500 (N-cm)

19,2 lb.-pi. 

2 600 (N-cm)

1/2 po. (Ф12,7)

26 lb.-pi. 

3 500 (N-cm)

26,5 lb.-pi. 

3 600 (N-cm)

5/8 po. (Φ16,0)

33 lb.-pi. 

4 500 (N-cm)

34,5 lb.-pi. 

4 700 (N-cm)

 

Figure 20

 

Figure 21

 

I

a

ttentIon

n

e

 

Serrez

 

paS

 

trop

 

fort

. U

n

 

coUple

 

exceSSif

 

peUt

 

caSSer

 

l

'

écroU

 

et

/

oU

 

gaUfrer

 

le

 

tUyaU

.

 

b

rancHements

 

électrIques

 

I

a

vertIssement

SeUleS 

leS

 

perSonneS

 

SatiSfaiSant

 

leS

 

exigenceS

 

D

'

Un

 « 

technicien

 » 

telleS

 

qUe

 

SpécifiéeS

 

par

 

l

'i

nStitUt

 

SUr

 

le

 

conDitionnement

 

De

 

l

'

air

le

 

chaUffage

et

 

la

 

réfrigération

 (ahri 

en

 

anglaiS

peUvent

 

UtiliSer

 

ceS

 

informa

-

tionS

. t

enter

 

D

'

inStaller

 

oU

 

De

 

réparer

 

cet

 

éqUipement

 

SanS

 

Une

 

telle

 

qUalification

 

peUt

 

entraîner

 

DeS

 

Dom

-

mageS

 

DU

 

proDUit

DeS

 

DommageS

 

corporelS

oU

 

la

 

mort

.

 

I

a

vertIssement

H

aute

 

tensIon

 ! 

D

éconnectez

 toUteS 

leS

 

alimentionS

 

électriqUeS

 

avant

 

D

'

effectUer

 

Un

 

entretien

. i

l

 

peUt

 

y

 

avoir

 

De

 

mUltipleS

 

SoUrceS

 

D

'

alimentation

. n

e

 

paS

 

le

 

faire

 

peUt

 

entraîner

 

DeS

 

DommageS

 

matérielS

DeS

 

DommageS

 

corporelS

 

oU

 

la

 

mort

 

DUS

 

à

 

Un

 

choc

 

électriqUe

. l

e

 

câblage

 

Doit

 

être

 

conforme

 

aU

 nec 

oU

 cec 

et

 

à

 

toUS

 

leS

 

coDeS

 

locaUx

. l

eS

 

câbleS

 

SoUS

-

DimenSionnéS

 

poUrraient

 

entraîner

 

DeS

 

perfor

-

manceS

 

faibleS

 

De

 

l

'

éqUipement

DeS

 

DommageS

 

De

 

l

'

éqUipement

 

oU

 

Un

 

incenDie

.

 

r

emarques

 

Importantes

 

◊ S

i

 

DeS

 

problèmeS

 

De

 

SécUrité

 

liéS

 

à

 

l

alimentation

 

Se

 

proDUiSent

l

'

Unité

 

ne

 

Doit

 

paS

 

être

 

connectée

 

avant

 

la

 

réSolUtion

 

De

 

ceS

 

problèmeS

 

◊ v

eillez

 

à

 

ce

 

qUe

 

l

'

alimentation

 

électriqUe

 

SUffiSe

 

à

 

alimenter

 

l

'

Unité

 

en

 

toUte

 

SécUrité

 

◊ l

a

 

tenSion

 

Devrait

 

être

 

compriSe

 

entre

 90% 

et

 110% 

De

 

la

 

tenSion

 

nominale

 

◊ l'

interrUpteUr

 

principal

 

et

 

le

 

paraSUrtenSeUr

 

Devraient

 

repréSenter

 1,5 

foiS

 

la

 

capacité

 

DU

 

coUrant

 

maxi

-

mal

 

De

 

l

'

Unité

 

et

 

Devraient

 

être

 

inStalléS

 

SUr

 

le

 

circUit

 

D

'

alimentation

 

◊ l'

Unité

 

Doit

 

être

 

correctement

 

reliée

 

à

 

la

 

terre

 

◊ c

onnectez

 

toUt

 

le

 

câblage

 

comme

 

illUStré

 

SUr

 

le

 

Schéma

 

De

 

câblage

 

électriqUe

 

SitUé

 

SUr

 

le

 

panneaU

 

De

 

l

'

Unité

 

extérieUre

 

◊ t

oUt

 

le

 

câblage

 

Doit

 

reSpecter

 

leS

 

coDeS

 

électriqUeS

 

locaUx

 

et

 

nationaUx

. l'

inStallation

 

Doit

 

être

 

effectUée

 

par

 

DeS

 

électricienS

 

qUalifiéS

.

 

•  L'unité doit comporter un circuit de dérivation individuel. 

  Remarque :

 L'épaisseur des fils et le courant nominal du fusible 

ou du disjoncteur sont déterminés par le courant admissible 
minimum du circuit et le dispositif de protection contre les 
surtensions indiqués sur la plaque signalétique, située sur le pan-
neau latéral de l'unité. Reportez-vous à la plaque signalétique 
avant de sélectionner le fil, le fusible et/ou le disjoncteur. 

Connexion du câble à l'unité intérieure 

  Remarque :

 Avant de réaliser tout travail électrique, coupez 

l'alimentation principale du circuit. 

I

a

vertIssement

H

aute

 

tensIon

 ! 

D

éconnectez

 toUteS 

leS

 

alimentionS

 

électriqUeS

 

avant

 

D

'

effectUer

 

Un

 

entretien

. i

l

 

peUt

 

y

 

avoir

 

De

 

mUltipleS

 

SoUrceS

 

D

'

alimentation

. n

e

 

paS

 

le

 

faire

 

peUt

 

entraîner

 

DeS

 

DommageS

 

matérielS

DeS

 

DommageS

 

corporelS

 

oU

 

la

 

mort

.

 

1.  Le fil de connexion interne et externe peut être branché sans 

avoir à retirer la grille. 

2.  Le fil de connexion entre l'unité intérieure et l'unité extérieure 

doit être un câble flexible approuvé, gainé en néoprène, avec 
une désignation de type H07RN-F ou plus robuste. 

3.  Soulevez le panneau de l'unité intérieure, retirez le couvercle 

du boîtier électrique en dévissant la vis comme indiqué sur la 
Figure 22. 

Содержание MSC 15 Series

Страница 1: ...P 5151 San Felipe Suite 500 Houston TX 77056 www goodmanmfg com or www amana hac com IO 412A April 2013 To prevent the risk of property damage personal injury or death do not store combustible materia...

Страница 2: ...steps in the orderpresentedshouldensureproperinstallation 2 4m 8 ft MOUNT WITH THE LOWEST MOVING PARTS AT LEAST ABOVE FLOOR OR GRADE LEVEL INDOORUNIT To avoid property damage personal injury or death...

Страница 3: ...crew A ST3 9x25 5 8 depending on model 4 Seal for cooling heating models only 1 5 Drain joint 1 Connection Pipe Assembly Liquid Side 1 4 6 35 3 8 9 52 Gas Side 3 8 9 52 1 2 12 7 5 8 16 0 7 Remote Cont...

Страница 4: ...lways use wall hole conduit when drilling metal grid metal plate etc 15 SEER MODELS A C D Indoor unit outline Figure 5A 12 000 Btu h A C D Figure 5B 18 000 Btu h 19 SEER MODELS Model B 18 000 A 31 790...

Страница 5: ...iping and wrapping Evenly bundle the tubing connecting cable and drain hose securely with tape as shown in Figure 12 Because the condensed water from the rear of the indoor unit gathers in the drain p...

Страница 6: ...x 250 21 5 549 11 276 MS 18 E15 30 x 23 x 11 760 x 590 x 285 21 530 11 5 290 MS 12 E19 30 x 23 x 11 760 x 590 x 285 21 530 11 5 290 MS 18 E19 33 x 27 5 x 12 5 840 x 700 x 320 22 560 13 335 Mounting Di...

Страница 7: ...ength Max Elevation Max Length Additional Refrigerant Gas Liquid ft m B ft m A ft m oz ft g m 1 2 1 4 12 7 6 35 3 8 1 4 9 52 6 35 3 8 1 4 9 52 6 35 1 2 1 4 12 7 6 35 26 25 8 0 3 20 26 25 8 66 20 0 3 2...

Страница 8: ...ring must comply with local and national electrical codes Installation should be done by qualified electri cians To avoid the risk of personal injury wiring to the unit must be properly polarized and...

Страница 9: ...ect proper cord diameter to fill the holes on the cord clamp Figure 23B 2 Remove caps on the conduit panel 3 Temporarily mount the conduit tubes not included on the conduit panel 4 Connect the power s...

Страница 10: ...test If no leaks exist proceed to System Evacuation System Evacuation Condensing unit liquid and suction valves are closed to contain the charge within the unit The unit is shipped with the valve ste...

Страница 11: ...removing refrig erant from a system Ensure the cylinder is free of damage which could lead to a leak or explosion Ensure the hydrostatic test date does not exceed 5 years Ensure the pressure rating me...

Страница 12: ...e operation can be done manually Manually controlling the unit is to be done only when the remote control is disabled or maintenance is required Grasp the panel sides and lift up the panel to an angle...

Страница 13: ...etension D connectez TOUTES les alimentions lectriques avant d effectuer un entretien Il peut y avoir de multiples sources d alimentation Ne pas le faire peut entra ner des dommages mat riels des domm...

Страница 14: ...us les codes et ordonnances locaux ou en leur absence selon la version la plus r cente du Code lectrique national L installation correcte de cette unit est d crite dans lessectionssuivantes Sivoussuiv...

Страница 15: ...de 1 Les pi ces doivent tre achet es s par ment Consultez le fournisseur pour con na tre les tailles de tuyaux Une paisseur de paroi du tuyau minimum de 1 32 po 0 7 mm est recommand e Remarque Les pi...

Страница 16: ...r frig rant et du condensat INSTALLATION 5 Le tuyau d vacuation doit tre install avec une l g re inclinai son vers le bas Voir Figure 6 Mur Int rieur Ext rieur 3 16 po 1 4 po 5 7 mm Figure 6 Le tuyau...

Страница 17: ...ation soit positionn sur le c t inf rieur du tubage empaquet Le positionner sur le c t sup rieur peut entra ner le d bordement du bac de purge l int rieur de l unit Le tuyau d vacuation doit tre incli...

Страница 18: ...longe de tuyau d vacuation fournie par l installateur Figure 16A Figure 16B Figure 16C Connexion des conduites de r frig rant Remarque La cause principale des fuites de r frig rant se situe au niveau...

Страница 19: ...arquesimportantes Si des probl mes de s curit li s l alimentation se produisent l unit ne doit pas tre connect e avant la r solution de ces probl mes Veillez ce que l alimentation lectrique suffise al...

Страница 20: ...rieure en d vissant la vis comme illustr sur la Figure 23A Figure 23A Figure 23B Remarque Le serre c ble doit tre d une taille ad quate pour pr venir le rel chement ou le glissement des c bles du ser...

Страница 21: ...e et maintenez le vide pendant 10 minutes Normalement lapressionmonteradurantcettep riode Remarques Si la pression augmente 1 000 microns ou moins et reste stable le circuit est consid r sans fuite vo...

Страница 22: ...t s du panneau et soulevez celui ci selon un angle qui le maintienne fixe et jusqu ce que vous entendiez un clic Appuyez sur le bouton de contr le manuel pour s lectionner AUTO ou COOL L unit fonction...

Страница 23: ...IO 412A www goodmanmfg com 11 Remarques...

Страница 24: ...12 www goodmanmfg com IO 412A Remarques...

Страница 25: ...zar el servicio t cnico Podr a haber m ltiples fuentes de alimentaci n Si no se cumple esta medida se podr an ocasionar da os mate riales lesiones personales o la muerte I Advertencia S LO pueden usar...

Страница 26: ...do con estas instrucciones de instalaci n y funcionamiento y seg n los c digos y reglamentos locales o en su defecto seg n la ltima edici n del C digo El ctrico Nacional La instalaci n adecuada de est...

Страница 27: ...orte de control remoto 1 Las piezas deben comprarse por separado Consulte a su proveedor sobre los tama os de las tuber as Se recomienda un m nimo de espesor de pared de tuber a de 1 32 pulgadas 0 7 m...

Страница 28: ...R 19 Figura 5C Instalaci n de tuber as de refrigerante y condensaci n Instalaci n 5 La manguera de drenaje deber a instalarse con una ligera pendiente hacia abajo vea la figura 6 Figura 6 No deber a i...

Страница 29: ...m s bajo del manojo de tuber as Colocarla en el lado superior puede hacer que la bandeja de drenaje se desborde dentro de la unidad La manguera de drenaje deber a inclinarse hacia abajo para asegurar...

Страница 30: ...necte la junta de drenaje con una manguera de drenaje de extensi n proporcionada por el instalador Figura 16A Figura 16B Figura 16C Conexiones del conducto de refrigerante Nota lacausaprincipaldep rdi...

Страница 31: ...enores que lo indicado podr an provocar un mal desempe o del equipo da os o incendios NotasImportantes Si tiene problemas de seguridad con el suministro el ctrico no deber a conectar la unidad hasta r...

Страница 32: ...ando el tornillo como se ve en la figura 23A Figura 23A Figura 23B Nota la abrazadera debe ser del tama o correcto para impedir que los cables se suelten o se deslicen de ella Elija el di metro apropi...

Страница 33: ...o durante 10 minutos Por lo general la presi n subir durante ese tiempo Notas Si la presi n se eleva a 1000 micrones o menos y permanece estable se considera que el sistema est libre de fugas proceda...

Страница 34: ...panel y lev ntelo hasta un ngulo en el que permanezca fijo y se oiga un clic Presione el bot n de control manual para seleccionar AUTOM TICO o FR O La unidad funcionar en modo forzado AUTOM TICO o FR...

Страница 35: ...IO 412A www goodmanmfg com 11 Notas...

Страница 36: ...12 www goodmanmfg com IO 412A Notas...

Отзывы: