Instrucciones de seguridad importantes ..................................... 1 
Inspección de envío ......................................................................1 
Códigos y normas ..........................................................................2 
Consideraciones sobre la instalación ........................................... 2 
Instalaciones en azoteas ...............................................................3 
Herramientas ................................................................................3 
Instalación de unidad interior .....................................................3 
Instalación de unidad exterior .....................................................5 
Conexiones del conducto de refrigerante .................................... 7 
Sistema eléctrico ...........................................................................8 
Conecte el cable a la unidad interior ........................................... 8 
Conecte el cable a la unidad exterior .......................................... 9 
Prueba de fugas (nitrógeno o indicios de nitrógeno) ................ 10 
Vaciamiento del sistema ............................................................10 
Manejo seguro del refrigerante ..................................................11 
Control de seguridad ..................................................................12 
Realización de pruebas ..............................................................12 

I

nstruccIones

 

de

 

segurIdad

 

Importantes

 

En todo el manual se utilizan los siguiente símbolos y etiquetas 
para indicar peligros de seguridad inmediatos o potenciales. 
Es responsabilidad del propietario y del instalador leer toda la 
información y las instrucciones de seguridad que acompañan estos 
símbolos y cumplir con ellas. Hacer caso omiso a la información de 
seguridad aumenta el riesgo de sufrir lesiones personales y provocar 
daños materiales o en el producto. 

I

a

dvertencIa

¡a

lto

 

voltaje

D

esconecte

 toDAs 

lAs

 

conexiones

 

eléctricAs

 

Antes

 

De

 

reAlizAr

 

el

 

servicio

 

técnico

. P

oDríA

 

hAber

 

múltiPles

 

fuentes

 

De

 

AlimentAción

. s

i

 

no

 

se

 

cumPle

 

estA

 

meDiDA

se

 

PoDríAn

 

ocAsionAr

 

DAños

 

mAte

-

riAles

lesiones

 

PersonAles

 

o

 

lA

 

muerte

.

 

I

a

dvertencIa

sólo 

PueDen

 

usAr

 

estA

 

informAción

 

lAs

 

PersonAs

 

que

 

cumPlAn

 

con

 

los

 

requisitos

 

De

 «

técnico

 

De

 

nivel

 

iniciAl

», 

como

 

mínimo

según

 

lo

 

esPecificA

 

el

 i

nstituto

 

De

 A

ire

 A

conDicionADo

, c

AlefAcción

 

y

 r

efrigerAción

 (Ahri, 

Por

 

sus

 

siglAs

 

en

 

inglés

). i

ntentAr

 

instAlAr

 

o

 

rePArAr

 

estA

 

uniDAD

 

sin

 

esA

 

exPerienciA

 

PueDe

 

cAusAr

 

el

 

DAño

 

Del

 

ProDucto

unA

 

lesión

 

PersonAl

 

o

 

lA

 

muerte

.

 

I

a

dvertencIa

g

ooDmAn

 

no

 

Asumirá

 

resPonsAbiliDAD

 

AlgunA

 

Por

 

lesiones

 

o

 

DAños

 

mAteriAles

 

que

 

surjAn

 

De

 

ProceDimientos

 

De

 

servicio

 

técnico

 

inADecuADos

. s

i

 

reAlizA

 

el

 

servicio

 

técnico

 

A

 

su

 

ProDucto

Asume

 

lA

 

resPonsAbiliDAD

 

Por

 

cuAlquier

 

lesión

 

PersonAl

 

o

 

DAños

 

mAteriAles

 

que

 

PueDAn

 

ProDucirse

 

como

 

resultADo

.

 

 

m

anual

 

de

 

InstalacIón

 

y

 

funcIonamIento

 

m

odelos

 

de

 

acondIcIonador

 

de

 

aIre

 

ambIental

 

tIpo

 «

splIt

» 

y

 

bomba

 

de

 

calor

 

MSC/MSH, SEER 15, 12,000 

y

 18,000 

unidadES

 

téRMiCaS

 

bRitániCaS

 (btu)/

HoRa

 • 230/208 

voltioS

 

MSC/MSH, SEER 19, 12,000 

y

 18,000 

unidadES

 

téRMiCaS

 

bRitániCaS

 (btu)/

HoRa

 • 230/208 

voltioS

U

nidad

 

exterior

© 2011, 2013 Goodman Manufacturing Company, L.P.  ◊  5151 San Felipe, Suite 500  ◊  Houston, Texas 77056

IO-412A www.goodmanmfg.com  4/13

Seer 15

Seer 19

Содержание MSC 15 Series

Страница 1: ...P 5151 San Felipe Suite 500 Houston TX 77056 www goodmanmfg com or www amana hac com IO 412A April 2013 To prevent the risk of property damage personal injury or death do not store combustible materia...

Страница 2: ...steps in the orderpresentedshouldensureproperinstallation 2 4m 8 ft MOUNT WITH THE LOWEST MOVING PARTS AT LEAST ABOVE FLOOR OR GRADE LEVEL INDOORUNIT To avoid property damage personal injury or death...

Страница 3: ...crew A ST3 9x25 5 8 depending on model 4 Seal for cooling heating models only 1 5 Drain joint 1 Connection Pipe Assembly Liquid Side 1 4 6 35 3 8 9 52 Gas Side 3 8 9 52 1 2 12 7 5 8 16 0 7 Remote Cont...

Страница 4: ...lways use wall hole conduit when drilling metal grid metal plate etc 15 SEER MODELS A C D Indoor unit outline Figure 5A 12 000 Btu h A C D Figure 5B 18 000 Btu h 19 SEER MODELS Model B 18 000 A 31 790...

Страница 5: ...iping and wrapping Evenly bundle the tubing connecting cable and drain hose securely with tape as shown in Figure 12 Because the condensed water from the rear of the indoor unit gathers in the drain p...

Страница 6: ...x 250 21 5 549 11 276 MS 18 E15 30 x 23 x 11 760 x 590 x 285 21 530 11 5 290 MS 12 E19 30 x 23 x 11 760 x 590 x 285 21 530 11 5 290 MS 18 E19 33 x 27 5 x 12 5 840 x 700 x 320 22 560 13 335 Mounting Di...

Страница 7: ...ength Max Elevation Max Length Additional Refrigerant Gas Liquid ft m B ft m A ft m oz ft g m 1 2 1 4 12 7 6 35 3 8 1 4 9 52 6 35 3 8 1 4 9 52 6 35 1 2 1 4 12 7 6 35 26 25 8 0 3 20 26 25 8 66 20 0 3 2...

Страница 8: ...ring must comply with local and national electrical codes Installation should be done by qualified electri cians To avoid the risk of personal injury wiring to the unit must be properly polarized and...

Страница 9: ...ect proper cord diameter to fill the holes on the cord clamp Figure 23B 2 Remove caps on the conduit panel 3 Temporarily mount the conduit tubes not included on the conduit panel 4 Connect the power s...

Страница 10: ...test If no leaks exist proceed to System Evacuation System Evacuation Condensing unit liquid and suction valves are closed to contain the charge within the unit The unit is shipped with the valve ste...

Страница 11: ...removing refrig erant from a system Ensure the cylinder is free of damage which could lead to a leak or explosion Ensure the hydrostatic test date does not exceed 5 years Ensure the pressure rating me...

Страница 12: ...e operation can be done manually Manually controlling the unit is to be done only when the remote control is disabled or maintenance is required Grasp the panel sides and lift up the panel to an angle...

Страница 13: ...etension D connectez TOUTES les alimentions lectriques avant d effectuer un entretien Il peut y avoir de multiples sources d alimentation Ne pas le faire peut entra ner des dommages mat riels des domm...

Страница 14: ...us les codes et ordonnances locaux ou en leur absence selon la version la plus r cente du Code lectrique national L installation correcte de cette unit est d crite dans lessectionssuivantes Sivoussuiv...

Страница 15: ...de 1 Les pi ces doivent tre achet es s par ment Consultez le fournisseur pour con na tre les tailles de tuyaux Une paisseur de paroi du tuyau minimum de 1 32 po 0 7 mm est recommand e Remarque Les pi...

Страница 16: ...r frig rant et du condensat INSTALLATION 5 Le tuyau d vacuation doit tre install avec une l g re inclinai son vers le bas Voir Figure 6 Mur Int rieur Ext rieur 3 16 po 1 4 po 5 7 mm Figure 6 Le tuyau...

Страница 17: ...ation soit positionn sur le c t inf rieur du tubage empaquet Le positionner sur le c t sup rieur peut entra ner le d bordement du bac de purge l int rieur de l unit Le tuyau d vacuation doit tre incli...

Страница 18: ...longe de tuyau d vacuation fournie par l installateur Figure 16A Figure 16B Figure 16C Connexion des conduites de r frig rant Remarque La cause principale des fuites de r frig rant se situe au niveau...

Страница 19: ...arquesimportantes Si des probl mes de s curit li s l alimentation se produisent l unit ne doit pas tre connect e avant la r solution de ces probl mes Veillez ce que l alimentation lectrique suffise al...

Страница 20: ...rieure en d vissant la vis comme illustr sur la Figure 23A Figure 23A Figure 23B Remarque Le serre c ble doit tre d une taille ad quate pour pr venir le rel chement ou le glissement des c bles du ser...

Страница 21: ...e et maintenez le vide pendant 10 minutes Normalement lapressionmonteradurantcettep riode Remarques Si la pression augmente 1 000 microns ou moins et reste stable le circuit est consid r sans fuite vo...

Страница 22: ...t s du panneau et soulevez celui ci selon un angle qui le maintienne fixe et jusqu ce que vous entendiez un clic Appuyez sur le bouton de contr le manuel pour s lectionner AUTO ou COOL L unit fonction...

Страница 23: ...IO 412A www goodmanmfg com 11 Remarques...

Страница 24: ...12 www goodmanmfg com IO 412A Remarques...

Страница 25: ...zar el servicio t cnico Podr a haber m ltiples fuentes de alimentaci n Si no se cumple esta medida se podr an ocasionar da os mate riales lesiones personales o la muerte I Advertencia S LO pueden usar...

Страница 26: ...do con estas instrucciones de instalaci n y funcionamiento y seg n los c digos y reglamentos locales o en su defecto seg n la ltima edici n del C digo El ctrico Nacional La instalaci n adecuada de est...

Страница 27: ...orte de control remoto 1 Las piezas deben comprarse por separado Consulte a su proveedor sobre los tama os de las tuber as Se recomienda un m nimo de espesor de pared de tuber a de 1 32 pulgadas 0 7 m...

Страница 28: ...R 19 Figura 5C Instalaci n de tuber as de refrigerante y condensaci n Instalaci n 5 La manguera de drenaje deber a instalarse con una ligera pendiente hacia abajo vea la figura 6 Figura 6 No deber a i...

Страница 29: ...m s bajo del manojo de tuber as Colocarla en el lado superior puede hacer que la bandeja de drenaje se desborde dentro de la unidad La manguera de drenaje deber a inclinarse hacia abajo para asegurar...

Страница 30: ...necte la junta de drenaje con una manguera de drenaje de extensi n proporcionada por el instalador Figura 16A Figura 16B Figura 16C Conexiones del conducto de refrigerante Nota lacausaprincipaldep rdi...

Страница 31: ...enores que lo indicado podr an provocar un mal desempe o del equipo da os o incendios NotasImportantes Si tiene problemas de seguridad con el suministro el ctrico no deber a conectar la unidad hasta r...

Страница 32: ...ando el tornillo como se ve en la figura 23A Figura 23A Figura 23B Nota la abrazadera debe ser del tama o correcto para impedir que los cables se suelten o se deslicen de ella Elija el di metro apropi...

Страница 33: ...o durante 10 minutos Por lo general la presi n subir durante ese tiempo Notas Si la presi n se eleva a 1000 micrones o menos y permanece estable se considera que el sistema est libre de fugas proceda...

Страница 34: ...panel y lev ntelo hasta un ngulo en el que permanezca fijo y se oiga un clic Presione el bot n de control manual para seleccionar AUTOM TICO o FR O La unidad funcionar en modo forzado AUTOM TICO o FR...

Страница 35: ...IO 412A www goodmanmfg com 11 Notas...

Страница 36: ...12 www goodmanmfg com IO 412A Notas...

Отзывы: