background image

Operating

 

Safety

 

Precautions

 

 

PLEASE

 

READ

 

THIS

 

PAGE

 

FOR

 

IMPORTANT

 

SAFTEY

 

INFORMATION!

 

 

 

 

A.

 

Hot

 

while

 

in

 

operation.

 

Keep

 

children,

 

clothing,

 

and

 

furniture

 

away.

 

Contact

 

may

 

cause

 

skin

 

burns.

 

B.

 

If

 

you

 

notice

 

a

 

smoldering

 

fire

 

(burnpot

 

full

 

but

 

no

 

visible

 

flame)

 

AND

 

a

 

heavy

 

smoke

 

buildup

 

in

 

firebox,

 

immediately

 

TURN

 

OFF

 

the

 

stove,

 

but

 

DO

 

NOT

 

unplug

 

it.

 

Do

 

not

 

open

 

the

 

door,

 

change

 

the

 

damper

 

setting

 

or

 

tamper

 

with

 

any

 

controls

 

on

 

the

 

stove.

 

Wait

 

until

 

firebox

 

clears,

 

and

 

blowers

 

shut

 

down,

 

do

 

as

 

instructed

 

in

 

PRE

START

UP

 

CHECK”

 

and

 

BUILDING

 

A

 

FIRE”,

 

then

 

attempt

 

to

 

restart

 

the

 

fire.

 

If

 

the

 

problem

 

persists

 

contact

 

your

 

dealer.

 

C.

 

WARNING:

 

DO

 

NOT

 

ADD

 

PELLETS

 

TO

 

THE

 

BURNPOT

 

BY

 

HAND

 

AT

 

ANY

 

TIME,

 

A

 

DANGEROUS

 

CONDITION

 

COULD

 

RESULT.

  

D.

 

WARNING:

 

DURING

 

THE

 

START

 

UP

 

CYCLE;

 

1)

 

DO

 

NOT

 

OPEN

 

THE

 

VIEWING

 

DOOR;

 

2)

 

DO

 

NOT

 

OPEN

 

THE

 

DAMPER

 

MORE

 

THAN

 

¼”;

 

3)

 

DO

 

NOT

 

USE

 

THE

 

FUEL

 

FEED

 

BUTTON

 

(UNLESS

 

PRIMING

 

THE

 

AUGER

 

AFTER

 

RUNNING

 

OUT

 

OF

 

PELLETS)

.

 

A

 

DANGEROUS

 

CONDITION

 

COULD

 

RESULT.

 

E.

 

Pellets

 

should

 

be

 

stored

 

in

 

a

 

dry

 

place.

 

The

 

pellets

 

should

 

not

 

be

 

stored

 

within

 

12”

 

of

 

the

 

stove.

 

F.

 

DO

 

NOT

 

STORE

 

OR

 

USE

 

FLAMMABLE

 

LIQUIDS,

 

ESPECIALLY

 

GASOLINE,

 

IN

 

THE

 

VICINITY

 

OF

 

YOUR

 

STOVE.

 

NEVER

 

USE

 

A

 

GAS

 

OR

 

PROPANE

 

TORCH,

 

GASOLINE,

 

GASOLINE

TYPE

 

LANTERN

 

FUEL,

 

KEROSENE,

 

CHARCOAL

 

LIGHTER

 

FLUID

 

OR

 

SIMILAR

 

FLUIDS

 

TO

 

START

 

OR

 

“FRESHEN

 

UP”

 

A

 

FIRE

 

IN

 

THIS

 

HEATER.

 

G.

 

WARNING:

 

DO

 

NOT

 

OVERFIRE

 

THIS

 

STOVE.

 

This

 

may

 

cause

 

serious

 

damage

 

to

 

your

 

stove

 

and

 

void

 

your

 

warranty.

 

It

 

also

 

may

 

create

 

a

 

fire

 

hazard

 

in

 

your

 

home.

 

IF

 

ANY

 

EXTERNAL

 

PART

 

OF

 

THE

 

UNIT

 

BEGINS

 

TO

 

GLOW,

 

YOU

 

ARE

 

OVERFIRING.

 

Immediately

 

press

 

the

 

“POWER”

 

switch

 

on

 

the

 

control

 

panel.

 

H.

 

KEEP

 

ALL

 

LOOSE

 

OR

 

MOVEABLE

 

HOUSEHOLD

 

COMBUSTIBLES,

 

SUCH

 

AS

 

FURNITURE,

 

DRAPES,

 

TOYS,

 

ETC.

 

AT

 

LEAST

 

THREE

 

FEET

 

FROM

 

THE

 

OPERATING

 

STOVE.

 

I.

 

Maintain

 

proper

 

ventilation.

 

It

 

is

 

important

 

that

 

adequate

 

oxygen

 

be

 

supplied

 

to

 

the

 

fire

 

for

 

the

 

combustion

 

process.

 

Modern

 

houses

 

are

 

often

 

so

 

well

 

insulated

 

that

 

it

 

may

 

become

 

necessary

 

to

 

open

 

a

 

window

 

slightly

 

or

 

install

 

an

 

outside

 

air

 

vent

 

to

 

provide

 

sufficient

 

combustion

 

air.

 

J.

 

Since

 

heating

 

with

 

a

 

solid

 

fuel

 

is

 

potentially

 

hazardous,

 

even

 

with

 

a

 

well

 

made

 

and

 

thoroughly

 

tested

 

stove,

 

it

 

would

 

be

 

wise

 

to

 

install

 

strategically

 

placed

 

smoke

 

detectors

 

and

 

have

 

a

 

fire

 

extinguisher

 

in

 

a

 

convenient

 

location,

 

near

 

an

 

exit.

 

K.

 

Do

 

not

 

open

 

stove

 

door

 

when

 

operating

 

unless

 

necessary.

 

This

 

will

 

create

 

a

 

dirty,

 

inefficient

 

burn

 

and

 

could

 

allow

 

smoke

 

spillage

 

or

 

sparks

 

to

 

escape.

 

L.

 

Do

 

not

 

permit

 

operation

 

by

 

young

 

children

 

or

 

those

 

unfamiliar

 

with

 

stove’s

 

operation.

 

M.

 

Do

 

not

 

service

 

or

 

clean

 

this

 

appliance

 

without

 

disconnecting

 

the

 

power

 

cord.

 

N.

 

Do

 

not

 

abuse

 

the

 

door

 

glass

 

by

 

striking,

 

slamming

 

or

 

similar

 

trauma.

 

Do

 

not

 

operate

 

the

 

stove

 

with

 

the

 

glass

 

removed,

 

cracked

 

or

 

broken.

 

O.

 

If

 

the

 

stove

 

is

 

installed

 

in

 

a

 

room

 

without

 

air

 

conditioning,

 

or

 

in

 

an

 

area

 

where

 

direct

 

sunlight

 

can

 

shine

 

on

 

the

 

unit,

 

it

 

is

 

possible

 

this

 

can

 

cause

 

the

 

temperature

 

of

 

the

 

stove

 

to

 

rise

 

to

 

operational

 

levels;

 

one

 

of

 

the

 

sensors

 

could

 

then

 

make

 

the

 

stove

 

start

 

on

 

its

 

own.

 

It

 

is

 

recommended

 

that

 

the

 

stove

 

be

 

unplugged

 

when

 

not

 

in

 

use

 

for

 

extended

 

amounts

 

of

 

time

 

(i.e.

 

during

 

the

 

summer

 

months).

 

 

 
 

PLEASE

 

READ

 

THIS

 

PAGE

 

FOR

 

IMPORTANT

 

SAFETY

 

INFORMATION!

 

Содержание MONROE

Страница 1: ...R APPLIANCE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW THE INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET FUEL BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODIL...

Страница 2: ... 9 Clearances 9 Floor Protection 9 Combustion Air Supply 10 Electrical Installation 10 Special Mobile Home Requirements 11 Example Installations 12 OPERATION 16 Button Controls 16 Proper Fuel 18 Pre Start Up Check 18 Building a Fire 19 Damper Control 19 Optional Thermostat 22 Operating Safety Precautions 23 MAINTENANCE 24 Ash Removal 24 Cleaning 26 Blowers 27 Chimney Cleaning 28 TROUBLESHOOTING GU...

Страница 3: ...unit or potential safety concern Read carefully and be sure you fully understand intent and meaning DANGER OF ELECTRICAL SHOCK While performing this action there is the possibility of electrical shock Be sure that the unit is disconnected from power while performing this action IMPORTANT PIECE OF INFORMATION Read carefully and be sure you fully understand the meaning and intent THIS IS AN ACTION T...

Страница 4: ...be unplugged when not in use for extended amounts of time i e during the summer months Do not unplug the stove if you suspect a malfunction Turn the stove off inspect it and call your dealer or qualified trained technician Do not use an adapter plug or sever the grounding plug Do not use a GFCI plug or circuit Do not route the electrical cord underneath in front of or over the stove Contact your l...

Страница 5: ...p the burn pot and eventually cut off the combustion air supply PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET FUEL BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Keep this manual handy for future reference THIS PELLET STOVE WHEN INSTALLED MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR...

Страница 6: ... SPECIFIED BY THE VENT MANUFACTURER Equivalent Vent Length EVL Prior to purchasing your pellet vent pipe type L you should plan your venting scenario in to determine the diameter of vent pipe you should use Pellet vent pipe comes in 3 and 4 diameter In order to determine if you can use 3 diameter pipe you need to calculate your EVL Equivalent Vent Length To properly calculate your EVL you should m...

Страница 7: ...hree elbows You should always avoid using four or more elbows You also want to avoid having elbows too close together Ideally any elbows in the exhaust configuration will be separated by 3 or more of straight pipe If the elbows cannot be spaced at least 3 apart you should use 4 diameter pipe to help reduce some of the restriction created by having elbows spaced so closely The increased pipe diamet...

Страница 8: ...3 Use only quality materials from known manufacturers and distributors 4 It is best to have the unit vented on the low pressure side of the house This is the side opposite of prevailing winds 5 Flex pipe is only approved for use inside of a masonry fireplace 6 Eliminate as much horizontal pipe and elbows as possible 7 Use the same size pipe diameter for your entire exhaust system 8 Do NOT plug the...

Страница 9: ...ve body Floor Protection Freestanding installations require a minimum 21 wide by 28 deep floor protection The stove must be placed on a continuous grouted joints noncombustible material such as ceramic tile cement board brick 3 8 millboard or equivalent or other approved or listed material suited for floor protection THE MATERIAL S USED MUST HAVE OR COMBINE TO HAVE A MINIMUM INSULATIVE RATING OF R...

Страница 10: ...at combustion air is easily available to the air inlet A closeable outside air register can be used in tightly insulated homes FOR A MOBILE HOME INSTALLATION THE STOVE MUST BE CONNECTED TO AN OUTSIDE SOURCE OF COMBUSTION AIR FOR MOBILE HOME INSTALLATIONS NO COMBUSTION AIR SUPPLY MAY EXCEED 10 FEET Electrical Installation Voltage variations can lead to serious performance problems The electrical sy...

Страница 11: ...fastened to the floor of the mobile home through the two holes in the rear of the stove using two lag bolts that are long enough to go through both a hearth if used and the floor of the home See figure 5 Figure 5 THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CELINING ROOF MUST BE MAINTAINED INSTALLATION SHOULD BE IN ACCORDANCE WITH THE MANUFACTURED HOME AND SAFETY STANDARD HUD CFR 328...

Страница 12: ...ality fuel and proper damper control The further you deviate from this recommended installation the less efficiently your unit will function NOTE Follow L Vent chimney manufacturer s instructions 1 Position stove adhering to clearances shown in Figure 1 2 Locate position of hole in wall directly behind stove exhaust vent refer to figure 3 3 Always maintain 3 clearance from combustible materials 4 ...

Страница 13: ...und or square hole in roof always 3 larger all the way around pipe Install upper edge and sides of flashing under roofing materials nail to the roof along upper edge Do not nail lower edge Seal nail heads with non hardening waterproof mastic 3 Apply non hardening waterproof mastic where the storm collar will meet the vent and flashing Slide storm collar down until it sits on the flashing Seal and ...

Страница 14: ...igure 9 4 Attach the L vent adapter a section of pipe and clean out tee making sure the clean out tee is centered in the chimney flue area Use RTV metallic tape and a minimum of three self taping screws at all joint connections to ensure a tight seal 5 Position the stove adhering to the clearances in Figure 1 6 Measure and build chimney top plate Cut out holes for chimney pipe and if used the outs...

Страница 15: ...0 5 Install and seal the top plate from step 3 with non hardening mastic Slip the storm collar over the pipe and while holding the pipe at the proper elevation affix the collar with a minimum of three stainless steel sheet metal screws Seal all joints and seams around the collar 6 Connect the horizontal pipe by pushing it through the hole in the masonry and lining it up with the branch in the tee ...

Страница 16: ...put If the stove has been shut off and you want to re start it while it is still warm the on off button must be held down for 2 seconds FUEL FEED BUTTON When the Fuel Feed button is pushed and held down the stove will feed pellets continuously into the burnpot While the stove s auger system is feeding pellets the green light in the Fuel Feed box will be on See figure 11 DO NOT USE THE FUEL FEED BU...

Страница 17: ...etting with the damper completely closed then you should use the Low Feed Adjustment button so that when the unit is on the number one heat level setting the 1 and 4 lights are on This will feed just a little bit more fuel to the fire You should also do this if you are using the unit with a thermostat in the High Low thermostat mode The Low Feed Adjustment button only changes the fuel feed rate fo...

Страница 18: ... or bind them c High ash content Poor quality pellets will often create smoke and dirty glass They will create a need for more frequent maintenance You will have to empty the burnpot plus vacuum the entire system more often Poor quality pellets could damage the auger Golden Eagle Stoves cannot accept responsibility for damage due to poor quality pellets Your dealer can recommend a good quality pel...

Страница 19: ... Make sure light is on c The damper should be completely closed or open no more than during start up This will vary depending on your installation and elevation Once fire is established adjust for desired flame increasing the amount the damper is open as the heat setting is increased See DAMPER CONTROL d Adjust feed rate to desired setting by pressing Heat Level Advance button If fire doesn t star...

Страница 20: ...warm the on off button must be held down for 2 seconds IF STOVE RUNS OUT OF PELLETS The fire goes out and the auger motor and blowers will run until the stove cools This will take 30 to 45 minutes After the stove components stop running the On Off and the BAR GRAPH lights stay on for 10 minutes After the 10 minutes the 3 light on the bar graph will flash and the On Off light will go off To restart...

Страница 21: ...n overheat situation in the stove and shut down the fuel feed or auger system 2 In case of a malfunctioning convection blower the high temperature thermodisc will automatically shut down the auger preventing the stove from overheating b If the combustion blower fails an air pressure switch will automatically shut down the auger Opening the stove door for more than 30 seconds during operation will ...

Страница 22: ...N section of this owner s manual HIGH LOW THERMOSTAT MODE When engaged in this mode the stove will automatically switch between two settings When warm enough it will switch to the 1 or low setting The room air blower will also slow to its lowest speed The Heat Level Advance setting on the bar graph will stay where it was initially set When the house cools below the thermostat setting the stove wil...

Страница 23: ...T OF THE UNIT BEGINS TO GLOW YOU ARE OVERFIRING Immediately press the POWER switch on the control panel H KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES SUCH AS FURNITURE DRAPES TOYS ETC AT LEAST THREE FEET FROM THE OPERATING STOVE I Maintain proper ventilation It is important that adequate oxygen be supplied to the fire for the combustion process Modern houses are often so well insulated that ...

Страница 24: ...r Brushed Ashes Emptied Interior Chambers Vacuumed Heat Exchange Tubes Two Passes Combustion Blower Blades Vacuumed Brushed Convection Blower Impeller Vacuumed Brushed Vent System Cleaned Gaskets Inspected Hopper end of season Emptied and vacuumed FAILURE TO CLEAN AND MAINTAIN THISUNIT AS INDICATED CAN RESULT IN POOR PERFORMANCE AND POTENTIAL SAFETY HAZARDS NEVER CLEAN THIS UNIT WHILE IT IS HOT AL...

Страница 25: ...urnpot make sure it is level and pushed all the way back down and that the igniter hole is to the rear when it is reinstalled see Figure 17 h Make sure the burnpot is level and pushed all the way in if the collar on the burnpot attached to the fresh air tube is not pushed back to meet the firebox wall the Hot Rod will not work properly MAKE SURE ASHES ARE COOL TO THE TOUCH BEFORE USING A VACUUM VA...

Страница 26: ...andle end with hole of the cleaning tool onto the cleaning rod refer to figure 13 The cleaner rod is located in the grill above the stove door Move the cleaner rod back and forth several times to clean the heat exchanger tubes When finished be sure to leave tube cleaner at the rear of the stove B Interior Chambers The four ash doors in the firebox of the Monroe can be removed for periodic cleaning...

Страница 27: ...vection blower is accessed by removing the stove s left side panel The combustion blower can be accessed by removing the right side panel The convection blower is on the left facing stove and the combustion blower is on the right When cleaning be careful not to dislodge balancing clip on convection blower or to bend fan blades Some stove owners lightly spray an anti creosote chemical on the fire t...

Страница 28: ...er will lead to some soot formation which will collect in the exhaust venting system The exhaust venting system should be inspected at least once every year or ton of pellets burned to determine if cleaning is necessary C Inspection and Removal The chimney connector and chimney should be inspected annually or per ton to determine if a creosote or fly ash build up has occurred If creosote has accum...

Страница 29: ...ke sure the ash door is properly latched and the gasket is sealing good If the stove has just a small hole for the ashes to fall through under the burnpot make sure the slider plate is in place to seal off the firebox floor 4 Vent pipe is incorrectly installed Check to make sure vent pipe installation meets criteria in owner s manual 5 The airflow switch wire connections are bad Check the connecto...

Страница 30: ... can lift the shaft out of the stove After you have removed the shaft inspect it for bent flights burrs or broken welds Remove any foreign material that might have caused the jam Also check the auger tube for signs of damage such as burrs rough spots or grooves cut into the metal that could have caused a jam 8 The auger motor has failed Remove the auger motor from the auger shaft and try to run th...

Страница 31: ... to the igniter Check the voltage going to the igniter during startup It should be a full current If the voltage is lower than full current check the wiring If the wiring checks out good the board is bad SMOKE SMELL COMING BACK INTO THE HOME Possible Causes Possible Remedies 1 There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Страница 32: ... of damage such as burrs rough spots or grooves cut into the metal that could have caused a jam 5 Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector 6 Bad control board If the fuse is good the wires and connectors check out good and the high limit switch did not trip test for power going to the auger motor If there is ...

Страница 33: ... the times match the auger timing chart If the auger motor runs constantly the board is bad 8 Combustion blower is not spinning fast enough Test the RPM on the blower after the blades have been cleaned The RPM should be approximately 3000 RPM 9 Bad Pellets Applies to GLASS SOOT S UP AT A VERY FAST RATE Only The brand of pellets or the batch of pellets that are being used may be of poor quality If ...

Страница 34: ...Electrical Diagram ...

Страница 35: ...ance Tool A TOOL 96 Burnpot A S BURNPOT Circuit Board Control Panel A E 101GE Combustion Blower A E 027 Convection Blower A E 033A Door Gasket C G 050 Door Glass C D 031 Exhaust Adapter 3 C M 050 Exhaust Adapter 4 A 4 VA Gasket Door C G 055 Gasket Combustion Blower Housing to Stove C G 101 Gasket Combustion Blower Motor to Housing C G 105 Hot Rod Igniter C E IGN Thermodisk Proof of Fire C E 090 22...

Страница 36: ... c If the unit must be examined at the consumer s residence it is the consumer s responsibility to contact a qualified stove technician and any service call charges incurred is the sole responsibility of the consumer as the warranty covers parts only d If the unit must be transported those charges will be the consumer s responsibility 2 When contacting Golden Eagle s technical support department e...

Отзывы: