background image

 

 

 
 
 

INSTALLATION AND 

OPERATING MANUAL

 

 

OIL BURNING STOVE 

ALASKA 2000 

 
 
 

Vérified and tested following 

CAN/CSA B140.3 et UL 896 standards by: 

Intertek Testing Services 

 

 
 
 
 
 

Fabricated by: 

 

1700 Léon-Harmel 

Québec, (Québec) 

G1N 4R9 

 

 

 

 

READ THESE INSTRUCTIONS AND SAVE FOR REFERENCE 

 

 

  

990830/45004A 

Содержание ALASKA 2000

Страница 1: ...IL BURNING STOVE ALASKA 2000 Vérified and tested following CAN CSA B140 3 et UL 896 standards by Intertek Testing Services Fabricated by 1700 Léon Harmel Québec Québec G1N 4R9 READ THESE INSTRUCTIONS AND SAVE FOR REFERENCE 990830 45004A ...

Страница 2: ...DATA HIMALAYA OIL BURNING STOVE COMBUSTIBLE OIL NO 1 OIL NO 2 HEAT INPUT kW BTU h kW BTU h Minimum 4 8 16 600 3 7 12 800 Maximum 10 7 36 800 10 3 35 550 FLOWRATE cc min litres h cc min litres h Minimum 9 9 0 59 8 5 0 35 maximum 17 3 1 04 16 1 0 97 MINIMUM DRAUGHT REQUIRED 0 05 INWC 0 05 INWC EFFICIENCY with fan 81 5 76 without fan 76 5 73 CLEARANCES TO COMBUSTIBLES Mm in Back 150 6 Side 150 6 Corn...

Страница 3: ...TION Table 1 CLEARANCES TO COMBUSTIBLES mm in Back 150 6 Side 150 6 Corners 150 6 Top 915 36 Flue Pipe 230 9 IMPORTANT It is essential to ensure that the room were the stove is located is sufficiently ventilated to provide an adequate air supply It is possible that if your home is well insulated that you will have to install an outside fresh air intake THE BURNING OF ONE LITRE OF FUEL OIL REQUIRES...

Страница 4: ...uired to use a stainless steel liner of 5 diameter inside the existing chimney ref B 139 4 2 2 6 standard The chimney has to reach a minimum of 15 high including stove pipes The chimney has to extend not less than 3 above the point it exits the roof and 2 higher than any roof building other obstacle within a horizontal distance of 10 ref standard B 139 4 2 2 11 CHEMNEY MINMUM HEIGHT Height of chem...

Страница 5: ...ef Standard B 139 4 2 5 5 DIRECT HORIZONTAL CONNECTION You may choose to connect your stove to the chimney with an horizontal flue pipe Figure 6 HORIZONTAL CONNECTION CEILING CONNECTION In the case where your chimney starts from the ceiling use one 90º elbow and the necessary straight sections Figure 7 CEILING CONNECTION DO NOT CONNECT MORE THAN ONE STOVE TO YOUR CHIMNEY FIX FLUE PIPES TOGETHER WI...

Страница 6: ...ner with a 7 16 key Figure 9A LEVELLING THE BURNER IMPORTANT IT IS VERY IMPORTANT TO LEVEL THE BURNER TO ALLOW A PROPER OIL VAPOR DISTRIBUTION THROUGH THE RINGS AND A BETTER OIL INLET Figure 9B LEVELLING THE BURNER FIXATION OF STOVE TO FLOOR The unit has to be stabilized in its location using the two fixation brackets Install the brackets on the two back adjustable legs figure 11 If the flooring i...

Страница 7: ...rom the tank toward the stove A 3 down slope is needed on the tank itself from the outlet towards the other end of the tank When the tank is installed outdoors it is preferable to use oil 1 to avoid viscosity problems NOTE THE BAROMETRIC TANK SHALL BE LOCATED SO THAT THE TANK WILL NOT BE EXPOSED TO THE DIRECT RAYS OF THE SUN OR BE ADJACENT TO ANY SOURCE OF INTENSE HEAT Figure 11 STOVE AND OIL TANK...

Страница 8: ...SURE THE DRAUGHT WITH ALL VENTILATION EQUIPMENT INSTALLED IN THE HOUSE RANGE HOOD BATHROOM FAN AIR EXCHANGER DRYER ETC IN OPERATION ref standard CAN CSA B 139 art 4 1 5 DRAUGHT REGULATOR An excessive draught is as bad as a draught to low The regulator controls the draught when it is excessive in high winds for exemple If the draught exceeds 0 08 in of water column you will have to adjust the regul...

Страница 9: ...FORE LIGHTING make sure that The tank is full The isolating valve is open See that the 3 rings are in the right position Each of them are stamped A B and C figure 13 Make sure that the flow regulating handle is in the 0 position figure 14b If it s not already done arm down the valve s lever located behind the stove figure 14A Wait for the valve to fill up and let the level stabilize BEFORE ATTEMPT...

Страница 10: ... the burner in order to keep it clean It allows a better combustion IF YOU MISS THE STOVE S LIGHTING ALWAYS WAIT FOR THE BURNER TO COOL DOWN TO ROOM TEMPERATURE BEFORE USING BURNING ALCOHOL AGAIN OR ELSE USE COMMERCIAL LIGHTING MATERIAL SOLID OR A PIECE OF COTTON DAMPED IN OIL IF FURTHER TO SOME MISOPERATION THE BURNER IS FILLED WITH IMPORTANT QUANTITIES OF OIL ALL OF THE OIL MUST FIRST BE REMOVED...

Страница 11: ...ack into place to finish the operation Figure 15 CLEANING TEE WHEN YOUR STOVE IS RUNNING ALWAYS KEEP THE CLEANING TEE LEVER PULLED BACK INTO PLACE ONCE A MONTH OR TWO Clean with a metallic brush The burner s shell The burner s rings The burner s catalyst in blue flame model AT THE BEGINNING OF EACH HEATING SEASON Clean the valve and tank filters Inspect the smoke box through the opening of the rea...

Страница 12: ...ME PRODUCES SMOKE AND SUITS THE GLASS Cleaning tee and or burner are dirty 1 Activate cleaning tee according to procedures 2 Schedule at the next shut off to clean the burner Orifice of plunger is partially plugged 1 Progressively increase flow to position 6 2 Push in manual consecutive times on the thermostatique regulator bottom to remove dirt form the orifice NOTE If the problem persist you may...

Страница 13: ...ne 1 Call a technician to the line 2 Make sure that the oil line has an adequate slope towards the tank Oil 2 is used in exterior tank 1 Use only oil 1 when tank is installed outside Partial or total obstruction by impurities in oil line or filters 1 Check filters on tank and valve 2 Ask a technician if the cleanness of the tank and line is OK THE STOVE MAKES NOISE GOES OUT AND LIGHT UP AGAIN The ...

Страница 14: ...rvention within the scope of their professional competence NO DESCRIPTION CODE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Handle 3 132 Door 2 9917 Asbestos sealing joint for window panes 3 40015 Pyrex slivers 3 60007 Door frame 2 9917 01 Asbestos sealing joint for door 3 40025 Lower front grill 2 9352 Top front grill 2 9965 Side panels 2 2 9950 Cover support system 2 9901 02 Fan cont...

Страница 15: ...Page 14 of 15 ...

Страница 16: ...nts are covered by the one year warranty as follows Woodstoves Ceramic glass refractory bricks gasket blower thermo disc and rheostat Gas units Ceramic glass valve burner piezo ignitor pilot blower and thermo disc Drolet Oil Stoves Burner valve Burner rings cleaning tee and electrical components EXCLUSIONS This warranty will not cover labour costs or any costs related to damages caused by faulty i...

Отзывы: