background image

INTRODUCTION

 

Thank

 

you

 

for

 

purchasing

 

the

 

Golden

 

Eagle

 

Wood

 

Pellet

 

Burning

 

Stove.

 

You

 

are

 

now

 

prepared

 

to

 

burn

 

wood

 

in

 

the

 

most

 

efficient,

 

convenient

 

way

 

possible.

 

To

 

achieve

 

the

 

safest,

 

most

 

efficient

 

and

 

most

 

enjoyable

 

performance

 

from

 

your

 

stove,

 

you

 

must

 

do

 

three

 

things:

 

1)

 

Install

 

it

 

properly;

 

2)

 

Operate

 

it

 

correctly;

 

and

 

3)

 

Maintain

 

it

 

regularly.

 

The

 

purpose

 

of

 

this

 

manual

 

is

 

to

 

help

 

you

 

do

 

all

 

three.

 

This

 

stove

 

has

 

been

 

independently

 

tested

 

to

 

ASTM

 

E1509

04

 

Standard

 

Specification

 

for

 

Room

 

Heaters,

 

Pellet

 

Fuel

 

Burning

 

Type

 

1,

 

ULC/ORD

 

1482

90

 

Standard

 

for

 

Solid

 

Fuel

 

Room

 

Heaters,

 

and

 

Oregon

 

Administrative

 

Rules

 

for

 

Mobile

 

Homes

 

(814

23

900

 

through

 

814

23

909)

 

and

 

Installation

 

as

 

a

 

Stove

 

Heater.

 

This

 

appliance

 

is

 

designed

 

specifically

 

for

 

use

 

only

 

with

 

pelletized

 

wood.

 

It

 

is

 

designed

 

for

 

residential

 

installation

 

according

 

to

 

current

 

national

 

and

 

local

 

building

 

codes

 

as

 

a

 

freestanding

 

room

 

heater.

 

It

 

is

 

also

 

approved

 

as

 

a

 

mobile

 

home

 

heater

 

which

 

is

 

designed

 

for

 

connection

 

to

 

an

 

outside

 

combustion

 

air

 

source.

 

This

 

stove

 

is

 

designed

 

to

 

provide

 

the

 

optimum

 

proportions

 

of

 

fuel

 

and

 

air

 

to

 

the

 

fire

 

in

 

order

 

to

 

burn

 

almost

 

free

 

of

 

smoke

 

and

 

soot.

 

Any

 

blockage

 

of

 

the

 

air

 

supply

 

to

 

or

 

from

 

the

 

stove

 

will

 

seriously

 

degrade

 

its

 

performance

 

and

 

will

 

be

 

evidenced

 

by

 

a

 

smoking

 

exhaust

 

and

 

a

 

sooting

 

window.

 

For

 

best

 

operation

 

the

 

ash

 

content

 

of

 

the

 

pellet

 

fuel

 

should

 

be

 

less

 

than

 

1%

 

and

 

the

 

calorific

 

value

 

approximately

 

8200

 

BTU/LB.

 

Avoid

 

high

 

ash

 

content

 

fuels

 

because

 

this

 

will

 

rapidly

 

fill

 

up

 

the

 

burn

 

pot

 

and

 

eventually

 

cut

 

off

 

the

 

combustion

 

air

 

supply.

 

 

 

PLEASE

 

READ

 

THIS

 

ENTIRE

 

MANUAL

 

BEFORE

 

INSTALLATION

 

AND

 

USE

 

OF

 

THIS

 

PELLET

 

FUEL

BURNING

 

ROOM

 

HEATER.

 

FAILURE

 

TO

 

FOLLOW

 

THESE

 

INSTRUCTIONS

 

COULD

 

RESULT

 

IN

 

PROPERTY

 

DAMAGE,

 

BODILY

 

INJURY

 

OR

 

EVEN

 

DEATH.

 

 

 

Keep

 

this

 

manual

 

handy

 

for

 

future

 

reference.

 

 

 

THIS

 

PELLET

 

STOVE,

 

WHEN

 

INSTALLED,

 

MUST

 

BE

 

ELECTRICALLY

 

GROUNDED

 

IN

 

ACCORDANCE

 

WITH

 

LOCAL

 

CODES,

 

OR

 

IN

 

THE

 

ABSENCE

 

OF

 

LOCAL

 

CODES,

 

WITH

 

THE

 

NATIONAL

 

ELECTRICAL

 

CODE,

 

ANSI/NFPA

 

70

.

 

 

 

 

The

 

authority

 

having

 

jurisdiction

 

(such

 

as

 

municipal

 

building

 

department,

 

fire

 

department,

 

fire

 

prevention

 

bureau,

 

etc.)

 

should

 

be

 

consulted

 

before

 

installation

 

to

 

determine

 

the

 

need

 

to

 

obtain

 

a

 

permit.

 

 

 

 

THE

 

STOVE

 

WILL

 

NOT

 

OPERATE

 

USING

 

NATURAL

 

DRAFT

 

OR

 

WITHOUT

 

A

 

POWER

 

SOURCE

 

FOR

 

THE

 

BLOWER

 

SYSTEMS

 

AND

 

FUEL

 

FEED

 

SYSTEM

 

AND

 

MUST

 

NOT

 

BE

 

BURNED

 

WITH

 

ANY

 

TYPE

 

OF

 

FUEL

 

BESIDES

 

WOOD

 

PELLETS.

 

 

 

 

COMMERCIAL

 

AND

 

INDUSTRIAL

 

INSTALLATIONS

 

OF

 

PELLET

 

STOVES

 

SHOULD

 

NOT

 

BE

 

USED

 

SINCE

 

OPERATIONAL

 

CONTROL

 

IS

 

OFTEN

 

NOT

 

WELL

 

MANAGED

 

IN

 

THESE

 

SETTINGS.

 

 

 

 

 
 
 

W

ARRANTY

 

R

EGISTRATION

 

To

 

receive

 

full

 

warranty

 

coverage,

 

you

 

will

 

need

 

to

 

show

 

evidence

 

of

 

the

 

date

 

you

 

purchased

 

your

 

stove.

 

We

 

suggest

 

that

 

you

 

make

 

a

 

copy

 

and

 

attach

 

your

 

sales

 

invoice

 

to

 

this

 

manual,

 

so

 

that

 

you

 

will

 

have

 

all

 

the

 

information

 

you

 

need

 

in

 

one

 

place

 

should

 

the

 

need

 

for

 

service

 

or

 

information

 

occur.

  

Also

 

be

 

sure

 

to

 

complete

 

the

 

warranty

 

registration

 

form

 

on

 

our

 

webpage

 

(preferred

 

method)

 

or

 

mail

 

in

 

the

 

one

 

that

 

came

 

with

 

the

 

stove.

  

When

 

registering

 

your

 

stove

 

for

 

warranty

 

a

 

copy

 

of

 

the

 

sales

 

invoice

 

must

 

be

 

included

 

either

 

in

 

electronic

 

format

 

if

 

registered

 

via

 

the

 

internet,

 

or

 

a

 

legible

 

copy

 

if

 

you

 

mail

 

in

 

the

 

warranty

 

registration

 

card

 

that

 

came

 

with

 

your

 

stove.

Содержание MONROE

Страница 1: ...R APPLIANCE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW THE INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET FUEL BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODIL...

Страница 2: ... 9 Clearances 9 Floor Protection 9 Combustion Air Supply 10 Electrical Installation 10 Special Mobile Home Requirements 11 Example Installations 12 OPERATION 16 Button Controls 16 Proper Fuel 18 Pre Start Up Check 18 Building a Fire 19 Damper Control 19 Optional Thermostat 22 Operating Safety Precautions 23 MAINTENANCE 24 Ash Removal 24 Cleaning 26 Blowers 27 Chimney Cleaning 28 TROUBLESHOOTING GU...

Страница 3: ...unit or potential safety concern Read carefully and be sure you fully understand intent and meaning DANGER OF ELECTRICAL SHOCK While performing this action there is the possibility of electrical shock Be sure that the unit is disconnected from power while performing this action IMPORTANT PIECE OF INFORMATION Read carefully and be sure you fully understand the meaning and intent THIS IS AN ACTION T...

Страница 4: ...be unplugged when not in use for extended amounts of time i e during the summer months Do not unplug the stove if you suspect a malfunction Turn the stove off inspect it and call your dealer or qualified trained technician Do not use an adapter plug or sever the grounding plug Do not use a GFCI plug or circuit Do not route the electrical cord underneath in front of or over the stove Contact your l...

Страница 5: ...p the burn pot and eventually cut off the combustion air supply PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET FUEL BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Keep this manual handy for future reference THIS PELLET STOVE WHEN INSTALLED MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL CODES OR...

Страница 6: ... SPECIFIED BY THE VENT MANUFACTURER Equivalent Vent Length EVL Prior to purchasing your pellet vent pipe type L you should plan your venting scenario in to determine the diameter of vent pipe you should use Pellet vent pipe comes in 3 and 4 diameter In order to determine if you can use 3 diameter pipe you need to calculate your EVL Equivalent Vent Length To properly calculate your EVL you should m...

Страница 7: ...hree elbows You should always avoid using four or more elbows You also want to avoid having elbows too close together Ideally any elbows in the exhaust configuration will be separated by 3 or more of straight pipe If the elbows cannot be spaced at least 3 apart you should use 4 diameter pipe to help reduce some of the restriction created by having elbows spaced so closely The increased pipe diamet...

Страница 8: ...3 Use only quality materials from known manufacturers and distributors 4 It is best to have the unit vented on the low pressure side of the house This is the side opposite of prevailing winds 5 Flex pipe is only approved for use inside of a masonry fireplace 6 Eliminate as much horizontal pipe and elbows as possible 7 Use the same size pipe diameter for your entire exhaust system 8 Do NOT plug the...

Страница 9: ...ve body Floor Protection Freestanding installations require a minimum 21 wide by 28 deep floor protection The stove must be placed on a continuous grouted joints noncombustible material such as ceramic tile cement board brick 3 8 millboard or equivalent or other approved or listed material suited for floor protection THE MATERIAL S USED MUST HAVE OR COMBINE TO HAVE A MINIMUM INSULATIVE RATING OF R...

Страница 10: ...at combustion air is easily available to the air inlet A closeable outside air register can be used in tightly insulated homes FOR A MOBILE HOME INSTALLATION THE STOVE MUST BE CONNECTED TO AN OUTSIDE SOURCE OF COMBUSTION AIR FOR MOBILE HOME INSTALLATIONS NO COMBUSTION AIR SUPPLY MAY EXCEED 10 FEET Electrical Installation Voltage variations can lead to serious performance problems The electrical sy...

Страница 11: ...fastened to the floor of the mobile home through the two holes in the rear of the stove using two lag bolts that are long enough to go through both a hearth if used and the floor of the home See figure 5 Figure 5 THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR WALL AND CELINING ROOF MUST BE MAINTAINED INSTALLATION SHOULD BE IN ACCORDANCE WITH THE MANUFACTURED HOME AND SAFETY STANDARD HUD CFR 328...

Страница 12: ...ality fuel and proper damper control The further you deviate from this recommended installation the less efficiently your unit will function NOTE Follow L Vent chimney manufacturer s instructions 1 Position stove adhering to clearances shown in Figure 1 2 Locate position of hole in wall directly behind stove exhaust vent refer to figure 3 3 Always maintain 3 clearance from combustible materials 4 ...

Страница 13: ...und or square hole in roof always 3 larger all the way around pipe Install upper edge and sides of flashing under roofing materials nail to the roof along upper edge Do not nail lower edge Seal nail heads with non hardening waterproof mastic 3 Apply non hardening waterproof mastic where the storm collar will meet the vent and flashing Slide storm collar down until it sits on the flashing Seal and ...

Страница 14: ...igure 9 4 Attach the L vent adapter a section of pipe and clean out tee making sure the clean out tee is centered in the chimney flue area Use RTV metallic tape and a minimum of three self taping screws at all joint connections to ensure a tight seal 5 Position the stove adhering to the clearances in Figure 1 6 Measure and build chimney top plate Cut out holes for chimney pipe and if used the outs...

Страница 15: ...0 5 Install and seal the top plate from step 3 with non hardening mastic Slip the storm collar over the pipe and while holding the pipe at the proper elevation affix the collar with a minimum of three stainless steel sheet metal screws Seal all joints and seams around the collar 6 Connect the horizontal pipe by pushing it through the hole in the masonry and lining it up with the branch in the tee ...

Страница 16: ...put If the stove has been shut off and you want to re start it while it is still warm the on off button must be held down for 2 seconds FUEL FEED BUTTON When the Fuel Feed button is pushed and held down the stove will feed pellets continuously into the burnpot While the stove s auger system is feeding pellets the green light in the Fuel Feed box will be on See figure 11 DO NOT USE THE FUEL FEED BU...

Страница 17: ...etting with the damper completely closed then you should use the Low Feed Adjustment button so that when the unit is on the number one heat level setting the 1 and 4 lights are on This will feed just a little bit more fuel to the fire You should also do this if you are using the unit with a thermostat in the High Low thermostat mode The Low Feed Adjustment button only changes the fuel feed rate fo...

Страница 18: ... or bind them c High ash content Poor quality pellets will often create smoke and dirty glass They will create a need for more frequent maintenance You will have to empty the burnpot plus vacuum the entire system more often Poor quality pellets could damage the auger Golden Eagle Stoves cannot accept responsibility for damage due to poor quality pellets Your dealer can recommend a good quality pel...

Страница 19: ... Make sure light is on c The damper should be completely closed or open no more than during start up This will vary depending on your installation and elevation Once fire is established adjust for desired flame increasing the amount the damper is open as the heat setting is increased See DAMPER CONTROL d Adjust feed rate to desired setting by pressing Heat Level Advance button If fire doesn t star...

Страница 20: ...warm the on off button must be held down for 2 seconds IF STOVE RUNS OUT OF PELLETS The fire goes out and the auger motor and blowers will run until the stove cools This will take 30 to 45 minutes After the stove components stop running the On Off and the BAR GRAPH lights stay on for 10 minutes After the 10 minutes the 3 light on the bar graph will flash and the On Off light will go off To restart...

Страница 21: ...n overheat situation in the stove and shut down the fuel feed or auger system 2 In case of a malfunctioning convection blower the high temperature thermodisc will automatically shut down the auger preventing the stove from overheating b If the combustion blower fails an air pressure switch will automatically shut down the auger Opening the stove door for more than 30 seconds during operation will ...

Страница 22: ...N section of this owner s manual HIGH LOW THERMOSTAT MODE When engaged in this mode the stove will automatically switch between two settings When warm enough it will switch to the 1 or low setting The room air blower will also slow to its lowest speed The Heat Level Advance setting on the bar graph will stay where it was initially set When the house cools below the thermostat setting the stove wil...

Страница 23: ...T OF THE UNIT BEGINS TO GLOW YOU ARE OVERFIRING Immediately press the POWER switch on the control panel H KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES SUCH AS FURNITURE DRAPES TOYS ETC AT LEAST THREE FEET FROM THE OPERATING STOVE I Maintain proper ventilation It is important that adequate oxygen be supplied to the fire for the combustion process Modern houses are often so well insulated that ...

Страница 24: ...r Brushed Ashes Emptied Interior Chambers Vacuumed Heat Exchange Tubes Two Passes Combustion Blower Blades Vacuumed Brushed Convection Blower Impeller Vacuumed Brushed Vent System Cleaned Gaskets Inspected Hopper end of season Emptied and vacuumed FAILURE TO CLEAN AND MAINTAIN THISUNIT AS INDICATED CAN RESULT IN POOR PERFORMANCE AND POTENTIAL SAFETY HAZARDS NEVER CLEAN THIS UNIT WHILE IT IS HOT AL...

Страница 25: ...urnpot make sure it is level and pushed all the way back down and that the igniter hole is to the rear when it is reinstalled see Figure 17 h Make sure the burnpot is level and pushed all the way in if the collar on the burnpot attached to the fresh air tube is not pushed back to meet the firebox wall the Hot Rod will not work properly MAKE SURE ASHES ARE COOL TO THE TOUCH BEFORE USING A VACUUM VA...

Страница 26: ...andle end with hole of the cleaning tool onto the cleaning rod refer to figure 13 The cleaner rod is located in the grill above the stove door Move the cleaner rod back and forth several times to clean the heat exchanger tubes When finished be sure to leave tube cleaner at the rear of the stove B Interior Chambers The four ash doors in the firebox of the Monroe can be removed for periodic cleaning...

Страница 27: ...vection blower is accessed by removing the stove s left side panel The combustion blower can be accessed by removing the right side panel The convection blower is on the left facing stove and the combustion blower is on the right When cleaning be careful not to dislodge balancing clip on convection blower or to bend fan blades Some stove owners lightly spray an anti creosote chemical on the fire t...

Страница 28: ...er will lead to some soot formation which will collect in the exhaust venting system The exhaust venting system should be inspected at least once every year or ton of pellets burned to determine if cleaning is necessary C Inspection and Removal The chimney connector and chimney should be inspected annually or per ton to determine if a creosote or fly ash build up has occurred If creosote has accum...

Страница 29: ...ke sure the ash door is properly latched and the gasket is sealing good If the stove has just a small hole for the ashes to fall through under the burnpot make sure the slider plate is in place to seal off the firebox floor 4 Vent pipe is incorrectly installed Check to make sure vent pipe installation meets criteria in owner s manual 5 The airflow switch wire connections are bad Check the connecto...

Страница 30: ... can lift the shaft out of the stove After you have removed the shaft inspect it for bent flights burrs or broken welds Remove any foreign material that might have caused the jam Also check the auger tube for signs of damage such as burrs rough spots or grooves cut into the metal that could have caused a jam 8 The auger motor has failed Remove the auger motor from the auger shaft and try to run th...

Страница 31: ... to the igniter Check the voltage going to the igniter during startup It should be a full current If the voltage is lower than full current check the wiring If the wiring checks out good the board is bad SMOKE SMELL COMING BACK INTO THE HOME Possible Causes Possible Remedies 1 There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Страница 32: ... of damage such as burrs rough spots or grooves cut into the metal that could have caused a jam 5 Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector 6 Bad control board If the fuse is good the wires and connectors check out good and the high limit switch did not trip test for power going to the auger motor If there is ...

Страница 33: ... the times match the auger timing chart If the auger motor runs constantly the board is bad 8 Combustion blower is not spinning fast enough Test the RPM on the blower after the blades have been cleaned The RPM should be approximately 3000 RPM 9 Bad Pellets Applies to GLASS SOOT S UP AT A VERY FAST RATE Only The brand of pellets or the batch of pellets that are being used may be of poor quality If ...

Страница 34: ...Electrical Diagram ...

Страница 35: ...ance Tool A TOOL 96 Burnpot A S BURNPOT Circuit Board Control Panel A E 101GE Combustion Blower A E 027 Convection Blower A E 033A Door Gasket C G 050 Door Glass C D 031 Exhaust Adapter 3 C M 050 Exhaust Adapter 4 A 4 VA Gasket Door C G 055 Gasket Combustion Blower Housing to Stove C G 101 Gasket Combustion Blower Motor to Housing C G 105 Hot Rod Igniter C E IGN Thermodisk Proof of Fire C E 090 22...

Страница 36: ... c If the unit must be examined at the consumer s residence it is the consumer s responsibility to contact a qualified stove technician and any service call charges incurred is the sole responsibility of the consumer as the warranty covers parts only d If the unit must be transported those charges will be the consumer s responsibility 2 When contacting Golden Eagle s technical support department e...

Отзывы: